         TITLE 'IGG09404 - STBREAK ROUTINE'                             00400020
IGG09404 CSECT                                                          00800020
*                                                                M3267  00900020
*                                                                 M3810 00950020
*0000433000,558000,670400,733800-735000,792000-999999            TS0015 01000020
*                                                                M4283  01100020
*                                                                 M5466 01150020
*********************************************************************** 01200020
*                                                                     * 01600020
*    RELEASE 23 DELETIONS/CHANGES                                     * 01800020
*    RELEASE 22 DELETIONS/CHANGES                                     * 02000020
*    RELEASE 21 DELETIONS/CHANGES                                     * 02200020
*0891736000                                                      S21008 02300021
*                                                                     * 02400020
* STATUS -                                                            * 02600020
*STATUS CHANGE LEVEL 002                                                02800021
*                                                                     * 03000020
* FUNCTION -                                                          * 03200020
*    THIS ROUTINE IS TO SERVE THE MACRO 'STBREAK'. IT IS PART OF SVC  * 03400020
*    94. IT IS TO SET THE STATUS BITS IN QCB TO REFLECT THE PRESENCE/ * 03600020
*    ABSENCE OF A BREAK FEATURE ON THE TERMINAL.  IT ONLY APPLIES TO  * 03800020
*    TERMINAL TYPES 1050 OR 2741 DIAL.  IF THE MACRO 'STBREAK' IS     * 04300020
*    ISSUED FOR TERMINALS OTHER THAN THE ABOVE MENTIONED TYPES, THE   * 04800020
*    FUNCTION IS IGNORED.                                             * 05300020
*                                                                     * 05800020
*    FOR 2741 OR 1050 DIAL TERMINAL TYPES, IF OPERAND IS-             * 06300020
*                                                                     * 06500020
*    YES (BIT 3 OF FLAG BYTE IN REG 1 IS ON) -                        * 06800020
*                                                                     * 07100020
*    1. SET QCBNOBRK OFF                                              * 07400020
*                                                                     * 07700020
*    NO (BIT 3 OF FLAG BYTE IN REG 1 IS OFF) -                        * 08300020
*                                                                     * 08800020
*    1. SET QCBNOBRK ON                                               * 09300020
*                                                                     * 09800020
* ENTRY POINTS -                                                      * 10100020
*         IGG09404 - CONTROL IS RECEIVED FROM MODULE IGC0009D VIA     * 10400020
*         XCTL ACCORDING TO THE ENTRY CODE 4                          * 10700020
*                                                                     * 11300020
* INPUT -                                                             * 11400020
*    REGISTER  3 HAS CVT ADDRESS                                      * 11500020
*    REGISTER  4 HAS TCB ADDRESS                                      * 11600020
*    REGISTER  5 HAS SVRB EXTENDED SAVE AREA ADDRESS                  * 11700020
*    REGISTER 11 HAS THE PARAMETERS                                   * 11800020
*                                                                     * 12300020
* OUTPUT -                                                            * 12600020
*    REGISTER 15 HAS RETURN CODE:                                     * 12900020
*           0 - SUCCESSFUL                                            * 13200020
*           4 - INVALID PARAMETER                                     * 13500020
*           8 - WRONG TERMINAL TYPE                                   * 13800020
*                                                                     * 14300020
* EXTERNAL REFERENCES -                                               * 14500020
*         TPUT - VIA SVC CALL                                         * 14700020
*         IEDQTNT - VIA BRANCH                                        * 14900020
*                                                                     * 15300020
* EXITS, NORMAL -                                                     * 15350020
*         SVC 3 WITH 0 IN REGISTER 15                                 * 15400020
*                                                                     * 15450020
* EXITS, ERROR -                                                      * 15500020
*         SVC 3 WITH 4 OR 8 IN REGISTER 15                            * 15550020
*                                                                     * 15600020
* TABLES/WORK AREAS -                                                 * 15650020
*    CONTROL BLOCKS ARE DESCRIBED IN THE DSECTS AT END OF LISTING     * 15700020
*    XCTL TABLE PRECEDES SAID DSECTS                                  * 15750020
*                                                                     * 15800020
* ATTRIBUTES -                                                        * 15850020
*    REENTRANT, REFRESHABLE, SUPERVISOR MODE, DISABLED AND ENABLED    * 15900020
*                                                                     * 15950020
* CHARACTER CODE DEPENDENCY -                                         * 16000020
*    THIS MODULE IS NOT CHARACTER DEPENDENT                           * 16050020
* NOTES -                                                             * 16100020
*    NONE                                                             * 16150020
*                                                                     * 16300020
*********************************************************************** 18400020
         SPACE 3                                                        18800020
********                                                                19200020
******** REGISTER EQUATES                                               19600020
********                                                                20000020
RZERO    EQU   0                        GENERAL PURPOSE REG             20400020
RONE     EQU   1                        GENERAL PURPOSE REG             20800020
RLCBSIZE EQU   1                        CONTAINS SIZE OF LCB            21200020
RLCBOFST EQU   1                        CONTAINS OFFSET TO DESIRED LCB  21600020
RPARM    EQU   2                        SAVE PARAMETERS                 22000020
RCVT     EQU   3                        POINTS AT CVT                   22400020
RTSCVT   EQU   3                        POINTS AT TSCVT                 22800020
RRPT     EQU   3                        POINTS AT TIOCRPT               23200020
RUCB     EQU   3                        POINTS AT UCB                   23400020
RTCB     EQU   4                        POINTS AT TCB                   23600020
RJSCB    EQU   4                        POINTS AT JSCB                  24000020
RDEB     EQU   4                       POINTS AT DEB                    24200020
RAVT     EQU   5                        POINTS AT AVT                   24400020
RDCB     EQU   5                        POINTS AT DCB                   24800020
RQCB     EQU   6                        POINTS AT QCB                   25200020
RTSB     EQU   7                        POINTS AT TSB                   25600020
RWORK    EQU   8                        WORK REGISTER                   26000020
RTT      EQU   8                        POINTS AT TERMINAL TABLE        26400020
RTSBSIZE EQU   9                        CONTAINS TSB SIZE               26800020
RTJID    EQU   10                       CONTAINS TJID                   27200020
RWORK1   EQU   11                       WORK REGISTER                   27400020
RBASE    EQU   12                       BASE REG                        27600020
RTCT     EQU   13                       POINTS AT TERMINAL CHARACTER    28000020
*                                       TABLE                           28400020
RTJB     EQU   13                       POINTS AT TJB                   28600020
R14      EQU   14                       CONTAINS RETURN ADDR            28800020
RLCB     EQU   14                       POINTS AT LINE CONTROL BLOCK    29200020
RCODE    EQU   15                       FOR RETURN CODE                 29600020
R15      EQU   15                       CONTAINS ADDR TO BRANCH TO      30000020
RLNNO    EQU   15                       CONTAINS RELATIVE LINE NUMBER   30400020
         SPACE 3                                                        30800020
********                                                                31200020
******** EQUATES FOR MASK, DISPLACEMENT AND LENGTH                      31600020
********                                                                32000020
D0       EQU   0                        DISPLACEMENT OF 0               32400020
D1       EQU   1                        DISPLACEMENT OF 1               32800020
IDLE     EQU   X'17'                   IDLE CHARACTER FOR TPUT   TS0015 33000020
GOODTRM  EQU   X'18'                    MASK FOR VALID TERMINAL         33200020
M2       EQU   2                        MASK FOR SHIFTING REGISTER      33600020
M24      EQU   24                       MASK FOR SHIFTING REG           34000020
NOT      EQU   X'FF'                    MASK FOR BIT OFF                34800020
DEBSIZE  EQU   32                       SIZE OF BASIC SECTION OF DEB    34860020
D16      EQU   16                       DISPLACEMENT OF 16              34920020
D19      EQU   19                       DISPLACEMENT OF 19              34980020
M4       EQU   4                        MASK FOR SHIFTING REGISTER      35040020
M28      EQU   28                       MASK FOR SHIFTING REGISTER      35100020
EXIT     EQU   3                        EQUATE FOR RETURN TO CALLER     35130020
D96      EQU   96                       DISPLACEMENT OF 96              35160020
         SPACE 3                                                        35200020
********                                                                35600020
******** EQUATES FOR RETURN CODES                                       36000020
********                                                                36400020
CODEGOOD EQU   X'00'                    CODE FOR SUCCESSFUL COMPLETION  36800020
INVALID  EQU   X'04'                    CODE FOR INVALID PARM           37200020
TRMBAD   EQU   X'08'                    RETURN CODE FOR INVALID         37600020
*                                       TERMINAL TYPE                   38000020
         SPACE 3                                                        38400020
********                                                                38800020
******** SET UP BASE REGISTER AND ADDRESSABILITY                        39200020
********                                                                39600020
         BALR  RBASE,RZERO              SET UP BASE REG                 40000020
         USING *,RBASE                                                  40400020
         USING CVT,RCVT                                                 40800020
         USING IEDQAVTD,RAVT                                            41200020
         USING TCB,RTCB                                                 41600020
         USING TSB,RTSB                                                 42000020
         USING IEDQTRM,RTT                                              42400020
         USING IEDQQCB,RQCB                                             42800020
         USING IEDQLCB,RLCB                                             43200020
         LR    R14,RAVT                SAVE SVRB SAVEAREA        TS0015 43260020
*                                       POINTER                  TS0015 43320020
         LR    RONE,RWORK1              LOAD PARAMETER                  43400020
         LR    RPARM,RONE               SAVE PARAMETER                  43600020
         N     RONE,KEY                 TURN PARM BIT OFF               44000020
         LTR   RONE,RONE                ANY BIT ON                      44400020
         BNZ   PARMBAD                  BRANCH IF NOT ALL ZEROS         44800020
         SPACE 3                                                        45200020
********                                                                45600020
******** GET POINTER TO NECESSARY CONTROL BLOCKS                        46000020
********                                                                46400020
         L     RCVT,CVTTSCVT            REG HAS ADDR OF TSCVT           47600020
         DROP  RCVT                                                     48000020
         USING TSCVT,RTSCVT                                             48400020
         L     RTSCVT,TSCVTRPT          REG HAS ADDR OF TIOCRPT         48800020
         DROP  RTSCVT                                                   49200020
         USING TIOCRPT,RRPT                                             49600020
         L     RTSBSIZE,TIOCTSBS        HIGH ORDER BYTE OF REG HAS TSB  50000020
*                                       SIZE, REST OF REG HAS ADDR OF   50400020
*                                       TSB TABLE                       50800020
         LR    RTSB,RTSBSIZE            REG HAS SAME AS ABOVE           51200020
         SRL   RTSBSIZE,M24             LOW ORDER BYTE OF REG HAS TSB   51600020
*                                       SIZE                            52000020
         L     RJSCB,TCBJSCB            GET ADDR OF JSCB                52400020
         DROP  RTCB                                                     52800020
         USING IEZJSCB,RJSCB                                            53200020
         LH    RTJID,JSCBTJID           GET TJID                        53600020
         BCTR  RTJID,0                  DECREMENT TJID BY 1             54000020
         MR    RWORK,RTJID              GET OFFSET TO TSB TABLE         54400020
         AR    RTSB,RTSBSIZE            GET ADDR OF PARTICULAR TSB      54800020
         L     RCVT,CVTPTR              GET CVT ADDRESS                 54830020
         DROP  RRPT                                                     54860020
         USING CVT,RCVT                                                 54890020
         SSM   DISABLE                  DISABLE ALL INTERRUPT           54920020
         TM    CVTTCMFG,CVTTCRDY        IS TCAM RUNNING                 54950020
         BNO   RETURN                   BRANCH IF NOT TCAM UP           54960020
         L     RAVT,CVTAQAVT            LOAD ADDR OF TCAM DISPATCHER    54970020
         L     RAVT,0(RAVT)             LOAD ADDR OF AVT                54980020
         L     RTJB,TSBTJB-1            GET ADDR OF TJB                 55010020
         USING TJB,RTJB                                                 55040020
         TM    TJBSTAT2,TJBHUNG         DID USER HANG UP                55070020
         BO    RETURN                   BRANCH IF USER HAS HANGUP       55130020
         L     RQCB,TSBQCB-1            GET ADDR OF DESTINATION OF QCB  55200020
         LH    RONE,TSBASRCE            GET INDEX TO TT ENTRY           55600020
         LR    RTSBSIZE,R14            SVRB SAVEAREA PTR IN      TS0015 55700020
*                                       RTSBSIZE                 TS0015 55800020
         N     RONE,AVTCLRHI            ZERO OUT HIGH ORDER TWO BYTES   56000020
         L     R15,AVTRNMPT             LOAD ADDR OF TCAM ROUTINE       56400020
         BALR  R14,R15                  BRANCH TO TCAM ROUTINE, UPON    56800020
*                                       RETURN, R1 HAS ADDR OF DESIRED  57200020
*                                       TERMINAL ENTRY                  57600020
         LR    RTT,RONE                 SAVE ADDR OF DESIRED TT         58000020
         SR    RTCT,RTCT                CLEAR REGISTER                  58400020
         IC    RTCT,TRMCHCIN            GET TCT INDEX                   58800020
         BCTR  RTCT,RZERO               DECREMENT INDEX BY 1            59200020
         SLL   RTCT,M2                  MULTIPLY BY TCT SIZE            59600020
         A     RTCT,AVTCSTCS            GET ADDR OF DESIRED TCT         60000020
         SPACE 3                                                        60400020
         L     RDCB,QCBDCBAD-1          GET ADDR OF DCB                 62000020
         DROP  RAVT                                                     62400020
         USING IHADCB,RDCB                                              62800020
         L     RLCB,DCBIOBAD            GET ADDR OF FIRST IOB           63200020
         LA    RZERO,LCBFLAG1-IEDQLCB   LOAD DISPLACEMENT OF LCB FROM   63600020
*                                       IOB                             64000020
         SR    RLCB,RZERO               GET ADDR OF FIRST LCB           64400020
         SR    RLCBSIZE,RLCBSIZE        CLEAR REGISTER                  64800020
         IC    RLCBSIZE,DCBEIOBX        GET LCB SIZE                    65200020
         SR    RLNNO,RLNNO              CLEAR REGISTER                  65600020
         IC    RLNNO,QCBRELLN           GET RELATIVE LINE NUMBER        66000020
         MR    RZERO,RLNNO              GET OFFSET OF DESIRED LCB       66400020
         AR    RLCB,RLCBOFST            REG HAS ADDR OF DESIRED LCB     66800020
         L     RDEB,DCBDEBAD            GET DEB ADDR                    66840020
         DROP  RJSCB                                                    66880020
         USING DEB,RDEB                                                 66920020
         SR    RONE,RONE                CLEAR REGISTER                  66960020
         IC    RONE,LCBUCBX             GET UCB INDEX                   67000020
         SR    R15,R15                 CLEAR REGISTER            TS0015 67010020
         IC    R15,DEBEXSCL             GET DEB EXTENT OFFSET    TS0015 67020020
         SLL   RONE,D0(R15)             GET PROPER DEB EXTENT    TS0015 67030020
*                                       OFFSET                   TS0015 67040020
         LA    RONE,DEBSIZE(RONE,RDEB)  POINT TO END OF BASIC DEB AND   67080020
*                                       ADD DEB EXTENT OFFSET VALUE     67120020
         L     RUCB,D0(RONE)            GET UCB ADDR                    67160020
         SPACE 3                                                        68000020
********                                                                68400020
******** TEST FOR 1050 OR 2741 TERMINAL                                 68800020
********                                                                69200020
         TM    D1(RTCT),GOODTRM         CHECK FOR 1050 OR2741 TERMINAL  69600020
         BNZ   TRMOK                    VALID TERMINAL, GO TO TRMOK     70000020
         SR    RONE,RONE                CLEAR REGISTER                  70020020
         IC    RONE,D16(RUCB)           PUT UCB MODEL CODE IN REG       70040020
         SLL   RONE,M28                 SHIFT OFF HIGH ORDER BITS       70060020
         SRL   RONE,M28                 SHIFT BACK                      70080020
         CH    RONE,ONE                 CHECK FOR 1050 TERMINAL         70100020
         BNE   WRNGTYPE                 BRANCH ON NOT 1050              70120020
         IC    RONE,D19(RUCB)           PUT UNIT TYPE IN REGISTER       70140020
         SRL   RONE,M4                  SHIFT OFF LOW ORDER 4 BITS      70160020
         CH    RONE,ONE                 CHECK FOR 1050 W/TYPE I ADAPTER 70180020
         BE    TRMOK                    BRANCH IF YES                   70200020
         CH    RONE,THREE               CHECK FOR 1050 W/TYPE II        70220020
*                                       ADAPTER                         70240020
         BE    TRMOK                    BRANCH IF 1050 WITH TYPE II     70290020
*                                       ADAPTER                         70340020
WRNGTYPE EQU   *                                                        70400020
         LA    RCODE,TRMBAD             LOAD RETURN CODE FOR INVALID    70800020
*                                       TERMINAL TYPE                   71200020
         SVC   EXIT                     RETURN CONTROL TO CALLING RTN   71600020
TRMOK    EQU   *                                                        72000020
         LTR   RPARM,RPARM              REVERSE BREAK                   72400020
         BNZ   BREAK                    BRANCH IF YES                   72800020
NOBREAK  EQU   *                                                        73200020
         OI    QCBTSOF1,QCBNOBUF        TURN ON QCBTSOF1                73260020
         OI    TSBSTAT,TSBLWAIT         TURN TSBSTAT                    73320020
         MVI   0(RTSBSIZE),IDLE         MOVE IN IDLE CHARACTER          73360020
         OI    TSBFLG3,TSBSPIT         NO AUTOPROMPT BY TSOUTPUT TS0015 73400020
         LA    RZERO,D1                SET BUFFER LENGTH         TS0015 73440020
         LA    RONE,0(,RTSBSIZE)        BUFFER ADDRESS                  73480020
         O     RONE,TPUTOPTN           LOAD TPUT OPTIONS         TS0015 73520020
         TPUT  (1),(0),R                ISSUE TPUT                      73540020
         L     RCVT,CVTPTR              GET CVT ADDRESS                 73542020
         TM    CVTTCMFG,CVTTCRDY        IS TCAM RUNNING                 73544020
         BNO   RETURN                   BRANCH IF TCAM IS NOT UP        73546020
         L     RTJB,TSBTJB-1            GET ADDR OF TJB                 73548020
         TM    TJBSTAT2,TJBHUNG         DID USER HANG UP                73550020
         BO    RETURN                   RETURN IF USER HAS HANGUP       73552020
         OI    QCBFLAG,QCBNOBRK         NOT A BREAK TERMINAL     S21008 73553021
         NI    QCBTSOF1,NOT-QCBNOBUF    TURN OFF QCBNOBUF               73554020
         NI    TSBSTAT,NOT-TSBLWAIT     TURN OFF TSBSTAT                73556020
         NI    TSBFLG3,NOT-TSBSPIT      TURN OFF TSBSPIT                73560020
         B     RETURN                   BRANCH TO RETURN                74000020
BREAK    EQU   *                                                        74400020
         NI    QCBFLAG,NOT-QCBNOBRK     TURN OFF QCBNOBRK BIT           74800020
RETURN   EQU   *                                                        75200020
         LA    RCODE,CODEGOOD           LOAD CODE FOR SUCCESS IN REG    75600020
         SVC   EXIT                     RETURN CONTROL TO CALLING RTN   76000020
PARMBAD  EQU   *                                                        76400020
         LA    RCODE,INVALID            LOAD RETURN CODE                76600020
         SVC   EXIT                     RETURN CONTROL TO USER          77200020
         DS    0F                       FORCE NEXT ITEM ON WORD         77600020
*                                       BOUNDARY                        78000020
KEY      EQU   *                                                        78400020
         DC    X'7FFFFFFF'              CONDITION FOR TESTING PARM      78800020
ONE      DC    H'1'                     CONSTANT OF ONE                 78840020
THREE    DC    H'3'                     CONSTANT OF THREE               78880020
TPUTOPTN DS    0F                                                TS0015 78890020
         DC    XL4'0E000000'           TPUT/HOLD/BREAK/CONTROL   TS0015 78900020
DISABLE  DC    X'00'                    MASK FOR RUNNING DISABLED       78906020
ENABLE   DC    X'FF'                    MASK FOR RUNNING ENABLED        78912020
         ORG   IGG09404+1008            MAKE MODULE 1K                  78920020
         DC    C'04    '                INFORMATION FOR XCTL BY TTR     78960020
         DC    H'0'                     FILLER HALFWORD                 79000020
         DC    F'0'                     DUMMY WORD                      79040020
         DC    C'094'                   INFORMATION FOR FIRST LOAD SVC  79080020
         DC    AL1(126)                 POINTS TO START OF XCTL TABLE   79120020
         SPACE 2                                                 TS0015 79720020
         TAVTD                                                          80320020
         SPACE 2                                                 TS0015 80920020
CVT      DSECT                                                          81520020
         CVT                                                            82120020
         SPACE 2                                                 TS0015 82720020
         DCBD  DSORG=TX                                          TS0015 83320020
         SPACE 2                                                 TS0015 83920020
DEB      DSECT                                                          84520020
         DS    CL28                                              TS0015 85120020
DEBEXSCL DS    CL1                                               TS0015 85720020
         SPACE 2                                                 TS0015 86320020
         IEZJSCB                                                        86920020
         SPACE 2                                                 TS0015 87520020
         TLCBD                                                          88120020
         SPACE 2                                                 TS0015 88720020
         TQCBD                                                          89320020
         SPACE 2                                                 TS0015 89920020
         IKJTCB                                                         90520020
         SPACE 2                                                 TS0015 91120020
         IKJTIOCP                                                       91720020
         SPACE 2                                                 TS0015 92320020
         TTRMD                                                          92920020
         SPACE 3                                                        93120020
         IKJTJB                                                         93320020
         SPACE 2                                                 TS0015 93520020
         IKJTSB                                                         94120020
         SPACE 2                                                 TS0015 94720020
         IKJTSCVT                                                       95320020
         SPACE 2                                                 TS0015 95920020
         END                                                            96520020
