         TITLE 'IFG0551H DETERMINES DEVICE TYPE, INITIALIZES WORK AREA' 00100000
         COPY  LCGASMSW                                                 00150000
IFG0551H CSECT ,                                                        00400021
*********************************************************************** 00500021
*                                                                     * 00600021
*          VS1 RELEASE 03.1 DELETIONS/CHANGES                         * 00650021
*SEE SA69185                                                    XA04640 00660021
*                                                                     * 00700021
*          RELEASE 25 DELETIONS/CHANGES                               * 00800021
*          RELEASE 24 DELETIONS/CHANGES                               * 00900021
*          RELEASE 23 DELETIONS/CHANGES                               * 01000021
*          RELEASE 22 DELETIONS/CHANGES                               * 01100021
*          RELEASE 21.8 DELETIONS/CHANGES                             * 01110021
*0000203000-216000,246000-247000,254000,335000-346000,452000-   SA69185 01120021
*0000462000,464000,526000                                       SA69185 01130021
*          RELEASE 21.7 DELETIONS/CHANGES                             * 01150001
*0000                                                           SA59750 01160001
*          RELEASE 21 DELETIONS/CHANGES                               * 01200021
*                                                                M0015  01250021
*0000442000-446000                                               A37870 01270021
*0000                                                            A37164 01280021
*0000                                                            A38013 01286021
*0000                                                            A40990 01292021
*0000435000                                                      A47776 01294021
*0000                                                           SA55590 01296021
*                                                                     * 01300021
* STATUS CHANGE LEVEL 000                                             * 01400021
*                                                                     * 01500021
* FUNCTION -                                                          * 01600021
*    THIS MODULE CONTAINS THE FUNCTION(S) OR PART(S) OF FUNCTION(S)-- * 01700021
*    DETERMINES DEVICE TYPE, INITIALIZE WORK AREA.                    * 01800021
*    REFER TO THE FOLLOWING 'FUNCTION PROLOG(S)' FOR DETAILS.         * 01900021
*                                                                     * 02000021
* ENTRY POINTS -                                                      * 02100021
*    IFG0551H - ENTRY POINT VIA THE RESIDENT XCTL FROM THE FOLLOWING- * 02200021
*    INITIAL ENTRY --                                                 * 02300021
*    IFG0551F - FOR NORMAL EOV BASIC                                  * 02400021
*                                                                     * 02500021
* INPUT -                                                             * 02600021
*    REFER TO THE FOLLOWING 'FUNCTION PROLOG(S)'.                     * 02700021
*                                                                     * 02800021
* OUTPUT -                                                            * 02900021
*    REFER TO THE FOLLOWING 'FUNCTION PROLOG(S)'.                     * 03000021
*                                                                     * 03100021
* EXTERNAL REFERENCES -                                               * 03200021
*         IFG055RA - OPEN/CLOSE/EOV RESIDENT ROUTINE FOR XCTL AND     * 03300021
*            WAIT.                                                    * 03400021
*         REFER TO THE FOLLOWING 'FUNCTION PROLOG(S)'.                * 03500021
*                                                                     * 03600021
* EXITS, NORMAL -                                                     * 03700021
*    EXIT VIA THE RESIDENT ROUTINE XCTL TO THE FOLLOWING --           * 03800021
*       IFG0552R TO PROCESS TAPE INPUT STANDARD TRAILER LABELS.       * 03900021
*       IFG0551P TO PROCESS TAPE OUTPUT STANDARD TRAILER LABELS.      * 04000021
*       IFG0551T TO PROCESS TAPE OUTPUT UNLABELED VOLUME DISPOSITION. * 04100021
*       IFG0554B TO REPOSITION DA VOLUMES FOR SPAN RECORD PROCESSING. * 04200021
*       IFG0553P TO PROCESS DIRECT ACCESS INPUT.                      * 04300021
*       IFG0554P TO PROCESS DIRECT ACCESS OUTPUT.                     * 04400021
*       IFG0554R - TO PROCESS 2321 OUTPUT.                            * 04500021
*       IFG0551J TO READ IN JFCB EXTENSION BLOCK IF                   * 04600021
*                                PROCESSING GREATER THAN 5TH VOLUME   * 04700021
*       IFG0552X TO PROCESS EODAD AND UNIT RECORD.                    * 04800021
*       IFG0554N DIRECT ACCESS FEOV OUTPUT FUNCTION.                  * 04900021
*       IFG0552Z TAPE CONCATENATION FUNCTION.                         * 05000021
*       NSLETRLO TO PROCESS NON-STANDARD OUTPUT TRAILER LABELS.       * 05100021
*       NSLETRLI TO PROCESS NON-STANDARD INPUT TRAILER LABELS.        * 05200021
*    REFER TO THE FOLLOWING 'FUNCTION PROLOG(S)'.                     * 05300021
*                                                                     * 05400021
* EXITS, ERROR -                                                      * 05500021
*    EXIT IS TO THE PROBLEM DETERMINATION MODULE IFG0190P, IF AN      * 05600021
*    ABEND SITUATION OCCURS IN THIS MODULE.  REFER TO THE FOLLOWING   * 05700021
*    'FUNCTION PROLOG(S)'.                                            * 05800021
*                                                                     * 05900021
* TABLES/WORK AREAS -                                                 * 06000021
*    REFER TO THE FOLLOWING 'FUNCTION PROLOG(S)'.                     * 06100021
*                                                                     * 06200021
* ATTRIBUTES -                                                        * 06300021
*    REENTRANT, REFRESHABLE, READ-ONLY, ENABLED, PRIVILEGED           * 06400021
*                                                                     * 06500021
* CHARACTER CODE DEPENDENCY -                                         * 06600021
*    CLASS ONE CHARACTER CODE DEPENDENCY - THE EBCDIC CHARACTER CODE  * 06700021
*    WAS USED FOR ASSEMBLY.  THE MODULE MUST BE REASSEMBLED IF A      * 06800021
*    DIFFERENT CHARACTER SET IS USED FOR EXECUTION.                   * 06900021
*                                                                     * 07000021
* NOTES -                                                             * 07100021
*    REFER TO THE FOLLOWING 'FUNCTION PROLOG(S)'.                     * 07200021
*                                                                     * 07300021
*********************************************************************** 07400021
         EJECT                                                          07500021
*********************************************************************** 07600021
*                                                                     * 07700021
*                          FUNCTION PROLOG                            * 07800021
*                                                                     * 07900021
*********************************************************************** 08000021
*                                                                     * 08100021
* FUNCTION NAME -                                                     * 08200021
*    DETERMINES DEVICE TYPE AND INITIALIZE WORK AREA FUNCTION.        * 08300021
*                                                                     * 08400021
* (STATUS) -                                                          * 08500021
*    NOT APPLICABLE                                                   * 08600021
*                                                                     * 08700021
* FUNCTION -                                                          * 08800021
*         1)  ESTABLISHES THREE VOLUME SERIALS(WHEN POSSIBLE)         * 08900021
*             IN WORK AREA - POSSIBLY IN CONJUNCTION WITH 551J.       * 09000021
*         2)  DETERMINES DEVICE TYPE AND XCTL'S TO THE PROPER MODULE. * 09100021
*                                                                     * 09200021
* ENTRY POINTS -                                                      * 09300021
*     ENTERED FROM THE FOLLOWING --                                   * 09400021
*      END-OF-VOLUME INITIAL READ JFCB FUNCTION.                      * 09500021
*                                                                     * 09600021
* INPUT -                                                             * 09700021
*       UPON ENTRY, REGISTER CONTENTS ARE --                          * 09800021
*           RDCB  - ADDRESS OF DCB AT END-OF-VOLUME.                  * 09900021
*           RCORE - ADDRESS OF 536 BYTE WORK AREA.                    * 10000021
*           RDEB  - ADDRESS OF DEB FOR DATA SET AT END-OF-VOLUME.     * 10100021
*           RTIOT - ADDRESS OF THE DATA SET ENTRY IN TIOT.            * 10200021
*           RUCB  - ADDRESS OF UCB FOR UNIT ON WHICH END-OF-VOLUME    * 10300021
*                   CONDITION EXISTS.                                 * 10400021
*                                                                     * 10500021
* OUTPUT -                                                            * 10600021
*        REGISTERS RDCB,RCORE,RDEB,RTIOT  ARE UNCHANGED.              * 10700021
*                                                                     * 10800021
* EXTERNAL REFERENCES -                                               * 10900021
*    REFER TO THE PRECEEDING MODULE PROLOG.                           * 11000021
*                                                                     * 11100021
* EXITS, NORMAL -                                                     * 11200021
*    REFER TO THE PRECEEDING MODULE PROLOG --                         * 11300021
*    TAPE INPUT TRAILER LABEL FUNCTION.                               * 11400021
*    TAPE OUTPUT TRAILER LABEL FUNCTION.                              * 11500021
*    TAPE OUTPUT END-OF-VOLUME FUNCTION.                              * 11600021
*    DIRECT ACCESS INPUT END-OF-VOLUME FUNCTION.                      * 11700021
*    DIRECT ACCESS OUTPUT END-OF-VOLUME FUNCTION.                     * 11800021
*    UNIT RECORD AND END-OF-DATA FUNCTION.                            * 11900021
*    DIRECT ACCESS OUTPUT FORCED-END-OF-VOLUME LOAD FUNCTION.         * 12000021
*    DIRECT ACCESS REPOSITIONING FUNCTION.                            * 12100021
*    END-OF-VOLUME DIRECT ACCESS OUTPUT 2321 LOAD FUNCTION.           * 12200021
*    JFCB EXTENSION FUNCTION.                                         * 12300021
*    END-OF-VOLUME TAPE INPUT VOLUME DISPOSITION, CONCATENATION.      * 12400021
*    NSLETRLO NON-STANDARD OUTPUT TRAILER LABEL FUNCTION.             * 12500021
*    NSLETRLI TO PROCESS NON-STANDARD INPUT TRAILER LABELS.           * 12600021
*                                                                     * 12700021
* EXITS, ERROR -                                                      * 12800021
*      NONE.                                                          * 12900021
*      REFER TO THE PRECEEDING MODULE PROLOG.                         * 13000021
*                                                                     * 13100021
* TABLES/WORK AREAS -                                                 * 13200021
*    THE OPEN, CLOSE, OR EOV WORK AREA AND THE WHERE-TO-GO (WTG)      * 13300021
*    TABLE ARE DESCRIBED BY THE DSECTS AT THE END OF THE LISTING.     * 13400021
*                                                                     * 13500021
* ATTRIBUTES -                                                        * 13600021
*    REFER TO THE PRECEEDING MODULE PROLOG.                           * 13700021
*                                                                     * 13800021
* CHARACTER CODE DEPENDENCY -                                         * 13900021
*    REFER TO THE PRECEEDING MODULE PROLOG.                           * 14000021
*                                                                     * 14100021
* NOTES -                                                             * 14200021
*        1. ALL EOV MODULES DEFINE THE 536 BYTES IN THE SAME FORMAT   * 14300021
*           INDICATED IN DSECT 'FORCORE'.                             * 14400021
*        2. ALL EOV MODULES USE SYMBOLIC REGISTERS AS SPECIFIED IN    * 14500021
*           THIS MODULE.                                              * 14600021
*                                                                     * 14700021
*      PROGRAM LOGIC MANUAL (PLM) LABEL TABLE                         * 14800021
         SPACE 1                                                        14900021
*  LABEL           FUNCTION                                    NAME   * 15000021
*                                                                     * 15100021
*********************************************************************** 15200021
         EJECT                                                          15300021
         USING UCB,RUCB                                                 15400021
         USING FORCORE,RCORE                                            15500021
*        USING TIOENTRY,RTIOT           DEFINE BASE TO TIOT DD ENTRY    15600021
         USING DEB,RDEB                                                 15700021
         USING IHADCB,RDCB                                              15800021
*                                                                       15900021
         BALR  RBASE,0                  ESTABLISH BASE                  16000021
         USING *,RBASE                                                  16100021
         OI    DCBOFLGS,DCBOBUSY        SET I/O SUPPORT BIT             16200021
         TM    DXXPATHS,WTGSMF          HAS TEST FOR SMF BEEN    A38013 16202021
*                                       ..MADE PREVIOUSLY-       A38013 16204021
         BO    EIN13400                 YES, DO NOT TEST AGAIN,  A38013 16206021
*                                       INSTEAD, BRANCH TO TURN  A38013 16208021
*                                       OFF SMF INDICATOR        A38013 16210021
         TM    JFCBTSDM,JFCSDS          SYSIN OR SYSOUT          A40990 16212021
         BO    EIN13450                 YES, BYPASS SMF          A40990 16214021
         L     RF,CVTPTR                                         A38013 16216021
         USING CVT,RF                                            A38013 16218021
         L     R7,CVTSMCA               GET PTR TO SMCA          A38013 16220021
         LTR   R7,R7                    TEST FOR SMF SYSTEM      A38013 16222021
         BZ    EIN13450                 BRANCH IF NO SMF         A38013 16224021
         USING SMCABASE,R7                                       A38013 16226021
         TM    SMCAOPT,SMCADSA          TEST FOR DATA SET INFO   A38013 16228021
         BNO   EIN13450                 BRANCH IF NOT REQUIRED   A38013 16230021
         TM    SMCAMISC,SMCAUSER+SMCAMAN                         A38013 16232021
*                                       ARE IBM RECORDS REQUIRED A38013 16234021
         BNO   EIN13450                 BRANCH IF NO             A38013 16236021
         DROP  R7                                                A38013 16238021
         L     R7,CVTTCBP                                        A38013 16240021
         L     R7,K4(R7)                GET TCB PTR              A38013 16242021
         L     R7,164(R7)               GET TCT PTR              A38013 16244021
         LTR   R7,R7                    TEST FOR TCT             A38013 16246021
         BZ    EIN13450                 BR IF NOT- BYPASS SMF    A38013 16248021
         OI    DXXPATHS,WTGSMF          IND SMF PROCESSING REQ'D A38013 16250021
         B     EIN13450                 CONTINUE PROCESSING      A38013 16252021
EIN13400 EQU   *                                                        16254021
         NI    DXXPATHS,X'FF'-WTGSMF    TURN OFF SMF INDICATOR   A38013 16256021
*                                       THIS WILL OCCUR ONLY ON  A38013 16258021
*                                       CONCATENATION WITH LIKE  A38013 16260021
*                                       ATTRIBUTES, WHEN THIS    A38013 16262021
*                                       MODULE CAN BE ENTERED    A38013 16264021
*                                       TWICE.                   A38013 16266021
EIN13450 EQU   *                                                 A38013 16268021
*                                                                       16280021
*********************************************************************** 16290021
*                                                                       16300021
*  IF 2321, NEED TO POINT TO MAIN UCB                                   16400021
         SR    RET,RET                  MUST BE ZERO UNLESS 2321        16500021
         LTR   RUCB,RUCB                DUMMY                           16600021
         BZ    EIN15550                 BR- PROCESS DUMMY AS EOD        16700021
         CLI   UCBID,UCBMAIN            TEST FOR 2321                   16800021
         BE    EIN13500                 BR IF NOT DATA CELL             16900021
         USING UCBDCELL,RUCB                                            17000021
         LH    RET,UCBDBBNR             PICK UP BB                      17100021
         SLL   RET,K4                   BB*16                           17200021
         LA    RET,UCBDCELL-UCBOB(RET)  BB*16 + MAIN UCB LENGTH         17300021
         SR    RUCB,RET                 MAIN UCB ADDR IN RUCB           17400021
*                                       RWTG MUST BE PRESERVED          17500021
         USING UCBOB,RUCB                                               17600021
*                                                                       17610021
*  DETERMINE CURRENT, NEXT, AND NEXT+1 VOLUME SERIAL NUMBERS            17620021
*  ACCORDING TO DEB VOLUME SEQUENCE NUMBER                              17630021
*                                                                       17640021
EIN13500 EQU   *                                                        17700021
         TM    UCBTBYT3,UCB3UREC        IS DEVICE UNIT RECORD   SA55590 17750021
         BO    EIN15300                 BRANCH IF UNIT RECORD   SA55590 17760021
         TM    DCBMACRF,DCBMEXCP        IS IT EXCP DCB                  17800021
         BNO   EIN13600                 NO BRANCH                       17900021
         TM    DCBMACRF,DCBMCOM         COMMON INTERFACE                18000021
         BNO   EIN13800                 NO BRANCH                       18100021
EIN13600 EQU   *                                                        18200021
         TM    DCBDSORG,DCBORGPO        DOES DCB INDICATE PARTITIONED   18300021
         BZ    EIN13800                 BR IF NO                        18400021
EIN13700 EQU   *                                                        18500021
         MVC   DXVOLSR1,JFCBVOLS        SERIAL NO. TO WORK AREA         18600021
         B     EIN15300                 BR TO CHECK FOR CONCATENATION   18700021
EIN13800 EQU   *                                                        18800021
         TM    JFCBIND1,K1              ARE WE PROCESSING A MEMBER      18900021
         BO    EIN13700                 BR IF YES                       19000021
*  ASSUME PS                                                            19100021
EIN13900 EQU   *                                                        19200021
         SR    R7,R7                                                    19300021
         TM    UCBTBYT3,DCBDEVDA        IS DEVICE DIRECT ACCESS         19400021
         BZ    EIN14000                 NO, GO                          19500021
         IC    R7,DEBNMEXT              NUMBER OF EXTENTS               19600021
         SLL   R7,K4                    EXTENT = 16 BYTES               19700021
         SH    R7,CON40U                SUBTRACT FOUR                   19800021
*                                       TOO MUCH FOR DIRECT ACCESS DEBS 19900021
EIN14000 EQU   *                                                        20000021
         LH    RC,DEBTVLSQ(R7)          GET DEB VOL SEQ NO.     SA69185 20010021
         N     RC,ANDCON                ZERO HI-ORDER 20 BITS   SA69185 20020021
         TM    DCBOFLGS,DCBORDBK        READ BACKWARDS           A38013 20100021
         BO    EIN14800                 BR IF YES                       20200021
         CH    RC,EOVDC30U              GREATER THAN 3RD VOLUME         21700021
         BH    EIN14400                 B,IF YES                        21800021
EIN14200 BCTR  RC,0                     REDUCE REG RB BY ONE            21900021
         MH    RC,CON60U                MULTIPLY BY SIX                 22000021
         LA    RD,JFCBVOLS              SERIAL NO ADDRESS               22100021
         AR    RD,RC                    COMPUTE FROM ADDRESS            22200021
         MVC   DXVOLSR,K0(RD)           MOVE 3 SER NO'S TO WRK SLOTS    22300021
EIN14300 EQU   *                                                        22400021
         B     EIN15300                 BR TO CHECK FOR CONCATENATION   22500021
*                                                                       22600021
EIN14400 CH    RC,EOVDC50U              GREATER THAN 5TH VOLUME         22700021
         BL    EIN14500                 VOL SEQ EQUALS FOUR             22800021
         BH    EIN14600                 VOL SEQ HIGHER THAN FIVE        22900021
         MVC   DXVOLSR1,JFCBVOLS+K24    VOL 5 TO WRK SLOT               23000021
         CLI   JFCBEXAD+K2,K0           JFCB EXTENSION PRESENT          23100021
         BE    EIN15300                 BRANCH IF NOT                   23200021
         B     EIN14700                 BR TO SETUP FOR XCTL            23300021
*                                                                       23400021
EIN14500 CLI   DXNOUNIT+K1,K1           ONE UNIT ONLY                   23500021
         BE    EIN14200                 B,IF YES                        23600021
         CLI   JFCBEXAD+K2,K0           TEST FOR JFCB EXTENSION         23700021
         BE    EIN14200                 BRANCH, IF NO                   23800021
         MVC   DXVOLSR(K12),JFCBVOLS+K18  VOL 4 AND 5 TO WRK SLOTS      23900021
EIN14600 EQU   *                                                        24000021
EIN14700 SH    RC,EOVDC50U              REDUCE COUNTER BY FIVE          24100021
         LA    R7,V1LD0V                EXTENSION OF BASIC EOV LOAD     24200021
         B     EIN17500                 BR TO DO XCTL TO RES RTN        24300021
*                                                                       24400021
EIN14800 EQU   *                                                        24500021
         CH    RC,EOVDC50U              IS VOLUME SEQ GREATER THAN 5    24800021
         BH    EIN15100                 B,IF YES                        24900021
         CH    RC,EOVDC30U              VOL SEQ LESS THAN THREE         25000021
         BL    EIN14900                 B,IF YES                        25100021
         SH    RC,EOVDC30U              SUBTRACT 3 FROM RC TO    A38013 25200021
*                                       USE AS INDEX REG         A38013 25300021
         MH    RC,CON60U                MULT VOL SEQ BY 6               25500021
         LA    RD,JFCBVOLS              ADDRESS OF SER. NOS. IN JFCB    25600021
         AR    RD,RC                    MOVE FROM ADDRESS               25700021
         MVC   DXVOLSR,K0(RD)           MOVE IN 3 SERIAL NUMBERS        25800021
         B     EIN15300                 BR TO CHECK FOR CONCATENATION   25900021
*                                                                       26000021
EIN14900 CH    RC,EOVDC10U              VOLUME NUMBER ONE               26100021
         BE    EIN15000                 B,IF YES                        26200021
         MVC   DXVOLSR2(K12),JFCBVOLS   MOVE IN 2 SERIAL NUMBERS        26300021
         B     EIN15300                 BR TO CHECK FOR CONCATENATION   26400021
*                                                                       26500021
EIN15000 MVC   DXVOLSR3,JFCBVOLS                                        26600021
         B     EIN15300                 BR TO CHECK FOR CONCATENATION   26700021
*                                                                       26800021
EIN15100 CH    RC,EOVDC70U              COMPARE VOL SEQ TO A SEVEN      26900021
         BL    EIN15200                 B,IF A SIX                      27000021
         BH    EIN14700                 BR TO SETUP FOR XCTL            27100021
         MVC   DXVOLSR1,JFCBVOLS+K24    MOVE IN VOL 5                   27200021
         B     EIN14700                 BR TO SETUP FOR XCTL            27300021
*                                                                       27400021
EIN15200 MVC   DXVOLSR1(K12),JFCBVOLS+K18  MOVE IN VOLS 4 AND 5         27500021
         B     EIN14700                 BR TO SETUP FOR XCTL            27600021
*                                                                       27700021
EIN15300 EQU   *                                                        27800021
         TM    DCBOFLGS,DCBOCON         IS CONCATENATION IN PROGRESS    28000021
         BZ    EIN15500                 BR IF NO                        28100021
         MVC   DXVOLSR3,DXVOLSR2        SHIFT SER NUMBERS               28200021
         MVC   DXVOLSR2,DXVOLSR1        FOR CONCATENATION               28300021
EIN15500 EQU   *                                                        28400021
*                                                                       28410021
*********************************************************************** 28420021
*                                                                       28430021
*                        CHECK IF DEVICE IS MAG TAPE                    28500021
         TM    UCBTBYT3,DCBDEVTP        IS IT TAPE DEVICE               28600021
         BO    EIN15600                 YES, GO                         28700021
*                                                                       28800021
*              TEST DEVICE TYPE FOR DIRECT ACCESS INDICATOR             28900021
         TM    UCBTBYT3,DCBDEVDA        IS IT DIRECT ACCESS             29000021
         BO    EIN16700                 YES, GO                         29100021
EIN15550 EQU   *                                                        29120021
         LA    R7,V1LD0N                PT TO ID OF EOD/CON-            29140021
*                                       ..CATENATION MODULE      M0015  29160021
         LA    RET,K16                  BR TABLE OFFSET FOR             29180021
*                                       ..CONCATENATION          M0015  29200021
         TM    DCBOFLGS,DCBOCON         IS THERE CONCATENATION-         29220021
         BO    EIN17600                 ..BR IF YES TO EXIT             29240021
         B     EIN17500                 ..ELSE BR TO LOAD BR            29260021
*                                       ..TABLE OFFSET FOR EOD   M0015  29280021
*                                                                       29300021
*...................................................................... 29310021
*                                                                       29320021
*              IS THIS INPUT OR OUTPUT MAG TAPE DATA SET                29400021
*                                                                       29500021
EIN15600 MVC   DXDEBMOD(K4),DEBDVMOD    DENS,MODE,UCB ADDR OF PP DEB    29600021
         NI    DXDEBMOD,DX6250          REMOVE PROB PROG TRTCH    99223 29700000
         TM    UCBTBYT2,UCB3TAPE        CHK FOR 7 TRK                   29800021
         BZ    EIN15700                 BRANCH IF NO                    29900021
         NI    DXDEBMOD,DXTRTMSK        TURN OFF 6250 BPI BIT     99223 29950000
         OI    DXDEBMOD,X'2B'           SET TRANSLATE MODE              30000021
EIN15700 EQU   *                                                        30100021
*                        CHECK IF DATA SET IS INPUT                     30200021
         TM    DCBOFLGS,DCBOWRIT        IF WRITE BIT ON,TREAT AS OUTPUT 30300021
         BO    EIN16500                 YES, GO                         30400021
*                                                                       30500021
*              IF EOVC BIT IS ON, CONCATENATION IS IN PROGRESS          30600021
*                                                                       30700021
*                        CHECK CONCATENATION INDICATOR                  30800021
         LA    R7,MOD2Z1H               SET UP FOR CONCAT. MOD ID       30900021
         LA    RET,K20                  AND BR TABLE OFFSET             31000021
         TM    DCBOFLGS,DCBOCON         CONCAT IN PROGRESS              31100021
         BO    EIN17600                 YES,GO                          31200021
*                                                                       31300021
*              WAS EOV CALLED BY FEOV EXECUTOR                          31400021
*                                                                       31500021
         LA    R7,V1LD0A                POINT TO INITIAL TAPE INPT LOAD 31600021
         LA    RET,K4                   BR TBL OFSET FOR NL,NSL,FEOV,   31700021
*                                            AND SYSIN                  31800021
         TM    DCBMACRF,DCBMEXCP        EXCP DCB                SA59750 31850001
         BO    EIN15800                 YES, BYPASS FEOV CHECK  SA59750 31860001
         TM    DCBCIND2,DCBC2FEO        CHECK FOR FEOV                  31900021
         BO    EIN17600                 YES, GO                         32000021
*                        DETERMINE IF LABELS SPECIFIED                  32100021
*              IS INPUT TAPE LABELED                                    32200021
*                                                                       32300021
EIN15800 TM    JFCBLTYP,JFCBLP+JFCNL    IS DATA SET UNLABELED           32400021
         BM    EIN17600                 YES, GO                         32500021
*                                                                       32600021
*              TEST INPUT LABELED TAPE FOR STANDARD INDICATOR           32700021
*                                                                       32800021
         TM    UCBWGT,UCBMOUNT          IS THIS VOLUME BEING USED AS    32900021
*                                       SYSIN                           33000021
         BO    EIN17600                 YES, ASSUME TAPE IS NOT LABELED 33100021
*                        CHECK STANDARD LABEL INDICATOR                 33200021
         TM    JFCBLTYP,JFCBAL+JFCSL    IS LABEL STANDARD OR ANSI       33300021
         BNZ   EIN17500                 YES, GO                         33400021
         CLC   JFCBNVOL(K1),DEBTVLSQ+K1  IF THIS IS EOF FOR NSL SA69185 34600021
         BNE   EIN16100                 NO,GO TO XCTL TO NSL            34700021
*                                       MODULE                          34800021
         L     RF,DCBEXLST              GET EXIT LIST ADDR TO           34900021
*                                       CHECK                           35000021
         LA    RF,K0(K0,RF)             FOR LABEL PROCESSING DEFERRED   35100021
         LTR   RF,RF                    IS THERE AN EXIT LIST ADDRESS   35200021
         BZ    EIN16100                 BR IF NOT XCTL TO NSLETRI       35300021
EIN16000 EQU   *                                                        35400021
         CLI   K0(RF),XLDEFNSL          EXIT LIST CODE BYTE EQ          35500021
*                                       X'0D'                           35600021
         BE    EIN16400                 YES,DEFER PROCESSING TILL       35700021
*                                       CLOSE                           35800021
         CLI   K0(RF),XLDEFNSL+LASTNTRY  EXIT LIST CODE BYTE EQ         35900021
*                                       X'8D'                           36000021
         BE    EIN16400                 YES,DEFER PROCESSING TILL       36100021
*                                       CLOSE                           36200021
         TM    K0(RF),LASTNTRY          LAST CODE BYTE ON LIST          36300021
         LA    RF,K4(K0,RF)             INCREMENT TO NEXT ENTRY         36400021
         BC    12,EIN16000              NO,GO CHECK NEXT FOR            36500021
*                                       X'0D'                           36600021
EIN16100 EQU   *                        YES,XCTL TO NSL MODULE          36700021
*                                                                       36800021
*        LOADING OF USER'S NON-STANDARD INPUT TRAILER LABEL HANDLER     36900021
*                                                                       37000021
         MVI   DXXMODNM+K7,CHARI        CHNGE TO NSL TRLR INPUT         37100021
         LA    RET,K8                   BRANCH TABLE OFFSET FOR RETURN  37200021
*                                       MOD IFG0552R (ALIAS IGG0550B)   37300021
EIN16200 EQU   *                                                        37400021
         MVC   DXXMODNM(K7),NSLNME      FILL IN NSL NAME                37500021
         NI    UCBWGT,X'EF'             INSURE REWIND BIT IS OFF        37600021
         LR    R8,RES                   SAVE RES PTR                    37700021
         LR    RES,RDEB                 PUT DEB IN R5 FOR NSL           37800021
         LA    RF,DXXCTL                LOAD XCTL PARM LIST ADDR        37900021
         LA    R0,DXXMODNM              LOAD MOD NAME ADDR              38000021
         XCTL  EPLOC=(0),DCB=0,SF=(E,(15))  GO TO NSL RTNE              38100021
*                                                                       38200021
*              LOADING OF TAPE INPUT EOV MODULE                         38300021
*                                                                       38400021
EIN16400 LA    R7,V1LD0A                INPUT TAPE PROCESSING           38500021
         B     EIN17600                 BR FOR RES XCTL                 38600021
*                                                                       38700021
*                        CHECK STANDARD LABEL INDICATOR                 38800021
*              TEST FOR STD LABELS INDICATOR IN JFCB                    38900021
EIN16500 TM    JFCBLTYP,JFCBAL+JFCSL    IS LABEL STANDARD OR ANSI       39000021
         BNZ   EIN16600                 YES, GO                         39100021
*                                                                       39200021
*              TEST FOR NON-STD LABELS INDICATOR IN JFCB                39300021
         MVI   DXXMODNM+K7,C'O'         SET NSL NAME TO OUTPUT          39400021
         TM    JFCBLTYP,JFCNSL          ARE LABELS NON-STD              39500021
         BO    EIN16200                 YES,GO TO XCTL                  39600021
*                                                                       39700021
*              LOADING OF TAPE OUTPUT EOV MODULE                        39800021
*                                                                       39900021
         LA    R7,V1LD0F                TAPE OUTPUT PROCESSING          40000021
         B     EIN17500                 BR TO DO RES XCTL               40100021
*                                                                       40200021
*              LOADING OF TAPE OUTPUT TRAILER LABEL PREPARATION         40300021
*                                                                       40400021
EIN16600 LA    R7,V1LD0E                TAPE OUTPUT TRLR PROCESSING     40500021
         B     EIN17500                 BR TO DO RES XCTL               40600021
*                                                                       40700021
*...................................................................... 40710021
*                                                                       40720021
*      DETERMINE IF DIRECT ACCESS DATA SET IS INPUT OR OUTPUT           40800021
EIN16700 SR    RD,RD                    TELL DA EOV THAT BASIC CALLS IT 40900021
         LTR   RET,RET                  TEST FOR 2321                   41000021
         BZ    EIN16800                 BR IF NOT DATA CELL             41100021
*  INPUT TO 2321 MODULES REQUIRES THAT                                  41200021
*  RUCB CONTAIN  POINTER TO SUB UCB                                     41300021
*  HOWEVER, AT THIS POINT RUCB POINTS TO MAIN UCB AND RWTG              41400021
*  CONTAINS OFFSET TO THE SUB UCB.                                      41500021
         ST    RUCB,DXCCW7              SAVE MAIN UCB ADDRESS           41600021
         AR    RUCB,RET                 REG  NOW ESTABLISHED            41700021
EIN16800 EQU   *                                                        41800021
         TM    DCBOFLGS,DCBOWRIT        HAS THE WRITE BIT BEEN SET      41900021
         BO    EIN17100                 YES, GO                         42000021
*                                                                     * 42100021
         SR    RET,RET                  ZERO RETURN REG FOR DA INPUT    42200021
***** LOAD THE REPOSITIONING MODULE                               ***** 42300021
*                                                                     * 42400021
         TM    DCBMACRF,DCBMEXCP        IS IT EXCP DCB           A47776 42450021
         BO    EIN16900                 YES GO TO DA PROCESSING  A47776 42460021
         TM    DCBIOBAD,DCBIODEB        TEST FURTHER                    42500021
         BZ    EIN16900                 NOT REPOSITIONING               42600021
*                                       FFEOV,BR                        42700021
         LA    R7,V1LD2D                REPOSITIONING PROCESSING        42800021
         B     EIN17500                 GO TO REPOSITIONING             42900021
*                                       MODULE                          43000021
*                                                                       43100021
*              LOADING OF DA INPUT EOV MODULE                           43200021
EIN16900 EQU   *                                                        43300021
*                                                                       43400021
         LA    R7,V1LD0I                DA INPUT PROCESSING      A47776 43500021
         B     EIN17500                 GO TO INITIAL FUNCTION   A47776 43600021
*                                                                       43700021
EIN17100 EQU   *                                                SA59750 43750001
         TM    DCBMACRF,DCBMEXCP        EXCP DCB                SA59750 43760001
         BO    EIN17150                 YES, BYPASS FEOV TEST   SA59750 43770001
*                        CHECK IF FEOV ISSUED                           43800021
*              DID CONTROL COME FROM FEOV EXECUTOR                      43900021
         TM    DCBCIND2,DCBC2FEO        FEOV                            44000001
         BO    EIN17300                 YES, GO                         44100021
*                                                                       44700021
EIN17150 EQU   *                                                SA59750 44750001
*              LOADING OF DA OUTPUT EOV MODULE                          44800021
         LTR   RET,RET                  TEST,BR IF NOT 2321             44900021
         BZ    EIN17200                 NOT,BR TO SET UP XCTL           45000021
         LA    R7,V1LD2K                2321 OUTPUT                     45100021
         B     EIN17500                 BR TO DA OUTPUT 2321 PROCESSING 46300021
*                                                                       46400021
EIN17200 EQU   *                                                        46500021
*                                                                       46600021
         LA    R7,V1LD0K                DA OUTPUT PROCESSING            46700021
         B     EIN17500                 BR TO DA OUTPUT PROCESSING      46800021
*                                                                       46900021
*              LOADING OF DA OUTPUT FEOV MODULE                         47000021
*                                                                       47100021
EIN17300 LA    R7,V1LD0Y                DA FEOV PROCESSING              47200021
         B     EIN17500                 BR TO DA FEOV PROCESSING        47300021
*                                                                       47800021
EIN17500 EQU   *                                                        47900021
         SR    RET,RET                  ZERO REG 14                     48000021
EIN17600 LA    RWTGC,DXXENTRY           SET R8 FOR RES RTN              48100021
         IECRES XCTL,(R7)               EXIT TO NEXT MOD                48300021
*                                                                       48400021
*********************************************************************** 48410021
*                                                                       48420021
*                   CONSTANTS                                           48500021
*                                                                       48600021
CON40U   DC    H'4'                     HWD CONSTANT OF 4               48700021
CON60U   DC    H'6'                     HWD CONSTANT OF 6               48800021
EOVDC10U DC    H'1'                     HWD CONSTANT OF 1               48900021
EOVDC30U DC    H'3'                     HWD CONSTANT OF 3               49100021
EOVDC50U DC    H'5'                     HWD CONSTANT OF 5               49200021
EOVDC70U DC    H'7'                     HWD CONSTANT OF 7               49300021
CHNOCT0U DC    X'4000000006'            CHAIN, 0 COUNT, READ OP         49400021
CHCTTI0U DC    X'6000000508'            CHAIN,SLI,5 COUNT,TIC OP        49500021
ANDCON   DC    F'4095'                  FWD CONSTANT OF 4095            49600021
         DC    X'FF'                    1 BYTE CONSTANT OF HEX 'FF'     49700021
NSLNME   DC    C'NSLETRL'               NSL TRLR LBL MOD NAME           49800021
IGG0U    DC    CL6'IFG055'              FIRST 6 BYTES OF MODULE NAMES   49900021
*                                                                       50000021
         XCTLTABL SVC=055,ID=(V1LD0A,2R,V1LD0E,1P,V1LD0F,1T,V1LD0I,3P, X50700021
               V1LD0K,4P,V1LD0N,2X,V1LD0Y,4N,V1LD2D,4B,V1LD2K,4R,      X51400021
               V1LD0V,1J,MOD2Z1H,2Z)                                    52100021
         IECDSECS CVT,DCB,UCB,DEB,MAIN,WTG,SMF,EXPAND=YES       SA69185 52600021
         IECEQU                                                         53100021
         END                                                            53200021
