         TITLE 'IFG0551Z EOV TAPE LABEL READER'                         00300021
         COPY  LCGASMSW                                                 00350000
IFG0551Z CSECT                                                          01200021
*********************************************************************** 01500021
*                                                                     * 01800021
*          VS1 RELEASE 3 CHANGES/DELETIONS                              01850003
*0000453000,462000,562000                                        XM3580 01900003
*0000488940,600500-601600                                        XM4077 01950003
*0000487500                                                      XM4079 02000003
*                                                                     * 02100021
*          RELEASE 25 DELETIONS/CHANGES                               * 02400021
*          RELEASE 24 DELETIONS/CHANGES                               * 02700021
*          RELEASE 23 DELETIONS/CHANGES                               * 03000021
*          RELEASE 22 DELETIONS/CHANGES                               * 03300021
*          RELEASE 21 DELETIONS/CHANGES                               * 03600021
*                                                                     * 03900021
* STATUS CHANGE LEVEL 000                                             * 04200021
*                                                                     * 04500021
* FUNCTION -                                                          * 04800021
*    THIS MODULE CONTAINS THE FUNCTION(S) OR PART(S) OF FUNCTION(S)-- * 05100021
*    EOV TAPE LABEL READER AND DENSITY CHECK FUNCTION.                * 05400021
*    REFER TO THE FOLLOWING 'FUNCTION PROLOG(S)' FOR DETAILS.         * 05700021
*                                                                     * 06000021
* ENTRY POINTS -                                                      * 06300021
*   IFG0551Z  - ENTRY POINT VIA THE RESIDENT XCTL FROM THE FOLLOWING- * 06600021
*   INITIAL ENTRY --                                                  * 06900021
*    IFG0551X - EOV TAPE OUT LABEL READER FUNCTION.                   * 07200021
*                                                                     * 07500021
* INPUT -                                                             * 07800021
*    REFER TO THE FOLLOWING 'FUNCTION PROLOG(S)'.                     * 08100021
*                                                                     * 08400021
* OUTPUT -                                                            * 08700021
*    REFER TO THE FOLLOWING 'FUNCTION PROLOG(S)'.                     * 09000021
*                                                                     * 09300021
* EXTERNAL REFERENCES -                                               * 09600021
*         IFG055RA - OPEN/CLOSE/EOV RESIDENT ROUTINE FOR XCTL AND     * 09900021
*            WAIT.                                                    * 10200021
*         REFER TO THE FOLLOWING 'FUNCTION PROLOG(S)'.                * 10500021
*                                                                     * 10800021
* EXITS, NORMAL -                                                     * 11100021
*    EXIT VIA THE RESIDENT ROUTINE XCTL TO THE FOLLOWING --           * 11400021
*       IFG0552B - PROCESS OUTPUT VOLUME HEADER LABEL FUNCTION.       * 11700021
*       IFG0552J - EMODVOL1, IF TAPE NOT IN SPECIFIED DENSITY.        * 12000021
*       NSLEHDRO - PROCESS NSL HEADER LABEL FUNCTION.                 * 12300021
*    REFER TO THE FOLLOWING 'FUNCTION PROLOG(S)'.                     * 12600021
*                                                                     * 12900021
* EXITS, ERROR -                                                      * 13200021
*    EXIT IS TO THE PROBLEM DETERMINATION MODULE IFG0190P, IF AN      * 13500021
*    ABEND SITUATION OCCURS IN THIS MODULE.  REFER TO THE FOLLOWING   * 13800021
*    'FUNCTION PROLOG (S)'.                                           * 14100021
*                                                                     * 14400021
* TABLES/WORK AREAS -                                                 * 14700021
*    REFER TO THE FOLLOWING 'FUNCTION PROLOG(S)'.                     * 15000021
*                                                                     * 15300021
* ATTRIBUTES -                                                        * 15600021
*    REENTRANT, REFRESHABLE, READ-ONLY, ENABLED, PRIVILEGED           * 15900021
*                                                                     * 16200021
* CHARACTER CODE DEPENDENCY -                                         * 16500021
*    CLASS ONE CHARACTER CODE DEPENDENCY - THE EBCDIC CHARACTER CODE  * 16800021
*    WAS USED FOR ASSEMBLY.  THE MODULE MUST BE REASSEMBLED IF A      * 17100021
*    DIFFERENT CHARACTER SET IS USED FOR EXECUTION.                   * 17400021
*                                                                     * 17700021
* NOTES -                                                             * 18000021
*    REFER TO THE FOLLOWING 'FUNCTION PROLOG(S)'.                     * 18300021
*                                                                     * 18600021
*********************************************************************** 18900021
         EJECT                                                          19200021
*********************************************************************** 19500021
*                                                                     * 19800021
*                          FUNCTION PROLOG                            * 20100021
*                                                                     * 20400021
*********************************************************************** 20700021
*                                                                     * 21000021
* FUNCTION NAME -                                                     * 21300021
*   EOV TAPE OUT LABEL READER AND DENSITY CHECK FUNCTION.             * 21600021
*                                                                     * 21900021
* (STATUS) -                                                          * 22200021
*    NOT APPLICABLE                                                   * 22500021
*                                                                     * 22800021
* FUNCTION -                                                          * 23100021
*   CHECK DENSITY OF EXISTING TAPE LABELS AGAINST DESIRED DENSITY.    * 23400021
*   IF AN ASCII TAPE IS NOT ACCESSIBLE, THE VOLUME WILL               * 23700021
*   BE UNLOADED AND A SCRATCH TAPE REQUESTED.                         * 24000021
*   DETERMINES IF NSL TAPES ARE TO BE PROCESSED.                      * 24300021
*                                                                     * 24600021
* ENTRY POINTS -                                                      * 24900021
*     ENTERED FROM THE FOLLOWING --                                   * 25200021
*     EOV TAPE OUT LABEL READER FUNCTION.                             * 25500021
*                                                                     * 25800021
* INPUT -                                                             * 26100021
*   REGISTERS RDCB=ADDRESS OF DCB,RCORE=ADDRESS OF 536 BYTE WORK      * 26400021
*   AREA,RDEB=ADDRESS OF DEB OF DCB,RTIOT=ADDRESS OF DDNAME ENTRY IN  * 26700021
*   THE TIOT, RUCB=ADDRESS OF UCB FOR CURRENT TAPE.                   * 27000021
*                                                                     * 27300021
* OUTPUT -                                                            * 27600021
*      REGISTERS RUCB,RCORE,RDEB,RDCB,RTIOT.(SEE INPUT)               * 27900021
*      INCORRECT VOLUME MESSAGE TO OPERATOR.                          * 28200021
*                                                                     * 28500021
* EXTERNAL REFERENCES -                                               * 28800021
*       NONE.                                                         * 29100021
*                                                                     * 29400021
* EXITS, NORMAL -                                                     * 29700021
*    REFER TO THE PRECEEDING MODULE PROLOG --                         * 30000021
*    PROCESS VOLUME HEADER LABEL FUNCTION.                            * 30300021
*    EMODVOL1 WHEN NOT IN SPECIFIED DENSITY FUNCTION.                 * 30600021
*    NSLEHDRO FUNCTION.                                               * 30900021
*                                                                     * 31200021
* EXITS, ERROR -                                                      * 31500021
*      ISSUED WITH ERROR CODE                                         * 31800021
*       144 - 637 ABEND - I/O ERROR READ LABEL,WRITE TAPE MARK,OR     * 32100021
*              TAPE POSITIONING.                                      * 32400021
*                                                                     * 32700021
* TABLES/WORK AREAS -                                                 * 33000021
*    THE OPEN, CLOSE, OR EOV WORK AREA AND THE WHERE-TO-GO (WTG)      * 33300021
*    TABLE ARE DESCRIBED BY THE DSECTS AT THE END OF THE LISTING.     * 33600021
*                                                                     * 33900021
* ATTRIBUTES -                                                        * 34200021
*    REFER TO THE PRECEEDING MODULE PROLOG.                           * 34500021
*                                                                     * 34800021
* CHARACTER CODE DEPENDENCY -                                         * 35100021
*    REFER TO THE PRECEEDING MODULE PROLOG.                           * 35400021
*                                                                     * 35700021
* NOTES -                                                             * 36000021
*        1. ALL EOV MODULES DEFINE THE 536 BYTES IN THE SAME FORMAT   * 36300021
*           INDICATED IN DSECT 'FORCORE'.                             * 36600021
*        2. ALL EOV MODULES USE SYMBOLIC REGISTERS AS SPECIFIED IN    * 36900021
*           THIS MODULE.                                              * 37200021
*        3. ON NORMAL EXITS FROM THIS MODULE, REGISTER CONTENTS ARE:  * 37500021
*           RDCB  - ADDRESS OF DCB AT END-OF-VOLUME.                  * 37800021
*           RCORE - ADDRESS OF 536 BYTE WORK AREA                     * 38100021
*           RDEB  - ADDRESS OF DEB FOR DATA SET AT END-OF-VOLUME.     * 38400021
*           RTIOT - ADDRESS OF THE DATA SET ENTRY IN TIOT.            * 38700021
*           RUCB  - ADDRESS OF UCB FOR NEXT TAPE.                     * 39000021
*                                                                     * 39300021
*********************************************************************** 39600021
         EJECT                                                          39900021
         USING FORCORE,RCORE                                            40200021
         USING UCB,RUCB                                                 40500021
         USING TIOENTRY,RTIOT                                           40800021
         USING DEB,RDEB                                                 41100021
         USING IHADCB,RDCB                                              41400021
*                                                                       41700021
*********************************************************************** 42000021
*              TAPE OUTPUT VOLUME LABEL READING STARTS HERE             42300021
*********************************************************************** 42600021
         BALR  RBASE,0                  ESTABLISH BASE                  42900021
         USING *,RBASE                                                  43200021
*                        IS VOLUME LABEL IN CORRECT DENS                43500021
*                                                                       43800021
         CLI   UCBTBYT4,X'03'           3400 SERIES DRIVE         99223 43850003
         BNE   ETO13700                 NO, BRANCH                99223 43900003
         CLI   UCBSENSN,K24             24 SENSE BYTES            99223 43950003
         BE    ETO13800                 YES, BRANCH               99223 44000003
ETO13700 EQU   *                                                        44100021
         TM    UCBTBYT1,PE+UCB1FEA6     IS THIS A PE DRIVE        99223 44400003
         BZ    ETO14700                 NO, BRANCH                99223 44700003
ETO13800 EQU   *                                                        45000021
         LA    R0,DXLBL+L'DXLBL         PREPARE                  XM3580 45300003
         ST    R0,DXCCW1                FOR                             45600021
         MVI   DXCCW1,CCWSENSE          SENSE COMMAND                   45900021
         XC    DXLBL+L'DXLBL(K18),DXLBL+L'DXLBL CLEAR SENSE AREA XM3580 45950003
         MVC   DXCCW1+K4(K4),SEN18P     LENGTH 18 BYTES, SLI     XM3580 46200003
         BAL   R8,ETO15500              BR TO EXCP/WAIT,CHK FOR IO/ERR  46500021
         MVC   DXCCW3,DXLBL+L'DXLBL     MOVE SENSE TO WORK       XM3580 46520003
         CLI   UCBTBYT4,X'03'           3400 SERIES DRIVE         99223 46530003
         BNE   ETO13850                 NO, BRANCH                99223 46540003
         CLI   UCBSENSN,K24             24 SENSE BYTES            99223 46542003
         BNE   ETO13850                 NO, BRANCH                99223 46544003
         L     RC,UCBXTN                GET ADDR OF UCB EXTENSION 99223 46546003
         MVC   K8(K2,RC),DXLBL+L'DXLBL+K15  MOVE UNIT ID TO UCB  XM3580 46548003
         XC    DXLBL+L'DXLBL(K18),DXLBL+L'DXLBL  CLEAR SENSE     XM4077 46548403
         TM    UCBTBYT1,PE+UCB1FEA6     IS THIS A PE DRIVE        99223 46548503
         BZ    ETO14700                 NO, BRANCH                99223 46548603
ETO13850 EQU   *                                                  99223 46548803
         TM    UCBTBYT1,UCB1FEA6        IS THIS 6250 UNIT         99223 46550003
         BO    ETO13855                 YES, BRANCH               99223 46600003
         TM    DXCCW3+K3,K4             IS DENSITY 1600                 46800021
         BO    ETO13900                 YES,BRANCH                      47100021
         CLI   DCBDEN,DCBD800           IF 800 BPI SPECIFIED            47400021
         BE    ETO14600                 BRANCH TO IND DENSITY           47700021
*                                                                       48000021
         B     ETO14000                 GO SEE IF TAPE CAN BE SAVED     48300021
*                                                                       48600021
ETO13855 EQU   *                        CHECK DENSITY OF UNIT     99223 48692003
         TM    DXCCW3+K6,UCBHIDD        ALT. DENSITY ON          XM4077 48700003
         BO    ETO13860                 NO,CHECK FOR 6250        XM4079 48750003
         CLI   DCBDEN,DCBD1600          YES,CHECK FOR 1600        99223 48800003
         BE    ETO14500                 GO SET UP FOR 1600        99223 48850003
         B     ETO14000                 GO SET ERROR BIT          99223 48860003
*                                                                 99223 48870003
ETO13860 EQU   *                        CHECK FOR 6250            99223 48880003
         CLI   DCBDEN,DCBD6250          WAS 6250 SPECIFIED        99223 48890003
         BNE   ETO14000                 NO,GO SET ERROR BIT       99223 48892003
         B     ETO14650                 YES,SET 6250 MODE        XM4077 48894003
ETO13900 EQU   *                        1600 BPI                        48900021
         CLI   DCBDEN,DCBD1600          1600 BPI SPECIFIED              49200021
         BE    ETO14500                 YES, BRANCH                     49500021
*                                                                       49800021
ETO14000 EQU   *                        HAS PREVIOUS EMODVOL1           50100021
*                                       LEFT                            50400021
         TM    JFCBMASK+K5,JFCDUAL      DUAL DEN ERROR BIT ON           50700021
         BO    ETO14400                 BR IF YES TO RECOVER            51000021
*                                                                       51300021
         OI    JFCBMASK+K5,JFCDUAL      SET DUAL DENSITY ERROR          51600021
*                                                                       51900021
ETO14100 MVI   DXCCW1,CCWREW            SET UP FOR REWIND               52200021
         BAL   R8,ETO15500              REWIND                          52500021
ETO14200 MVC   DXXMODNM,EMOD2P          GET ADR OF EMODVOL1             52800021
ETO14300 LA    R0,DXXMODNM              SET R0 TO NAME                  53100021
         LA    RF,DXXCTL                SET R15 TO XCTL AREA            53400021
         XCTL  EPLOC=(0),DCB=0,SF=(E,(15))  XCTL BY NAME                53700021
*                                                                       54000021
*  THE LABEL DUAL DENSITY ERROR BIT HAS BEEN LEFT ON BY PREVIOUS        54300021
*  PASS THROUGH EMODVOL1.                                               54600021
*  SET UP THE DESIRED DENSITY FOR THE TAPE VOLUME LABEL REWRITE.        54900021
*  CONTINUE TO READ HEADER LABELS AT THE CURRENT DENSITY.               55200021
*                                                                       55500021
ETO14400 EQU   *                                                        55800021
         NI    JFCBMASK+K5,ALLBITS-JFCDUAL  TURN OFF DEN ERROR BIT      56100021
         CLI   DCBDEN,DCBD6250          WAS 6250 BPI SPECIFIED   XM4077 56150003
         BE    ETO14650                 YES. BRANCH              XM4077 56200003
*                                                                       56400021
         CLI   DCBDEN,DCBD800           WAS 800 BPI DESIRED             56700021
         BE    ETO14600                 BR IF YES TO SET 800 BPI        57000021
*                                                                       57300021
*                                       ELSE DEFAULT TO 1600 BPI        57600021
*                                                                       57900021
*              SET UP DEBDVMOD WITH TRTCH AND DENSITY                   58200021
*                                                                       58500021
ETO14500 MVI   DEBDVMOD,DCBD1600        INDICATE 1600 DENSITY           58800021
         B     ETO14800                 BR TO CHK NSL,ANSI              59100021
ETO14600 MVI   DEBDVMOD,DX800           INDICATE 800 DENSITY            59400021
         B     ETO14800                 BR TO CHK NSL,ANSI              59700021
         SPACE                                                          60000021
ETO14650 EQU   *                        SET 6250 BPI MODE        XM4077 60050003
         MVI   DEBDVMOD,DCBD6250        SET MODE FOR 6250 BPI     99223 60200003
         B     ETO14800                 GO CHECK LABEL TYPE       99223 60250003
***                                                                     60300021
         SPACE                                                          60600021
ETO14700 EQU   *                        NOT A DUAL DENSITY DRIVE        60900021
         SPACE                                                          61200021
         MVC   DEBDVMOD,DCBDEN          DENSITY                         61500021
         OC    DEBDVMOD,DCBTRTCH        TAPE RECORDING TECHNIQUE        61800021
         TM    DCBTRTCH,X'38'           HAS TRTCH BEEN SPECIFIED  99223 62100003
         BNZ   ETO14800                 YES, BRANCH                     62400021
         OI    DEBDVMOD,X'30'           ASSUME TRANSLATE, CONVERT OFF   62700021
*                                      ODD PARITY, LOW DENSITY          63000021
*                                                                       63300021
*                                                                       63600021
ETO14800 EQU   *                                                        63900021
         TM    JFCBLTYP,JFCNSL          NSL SPEC                        64200021
         BO    ETO15200                 BR IF NSL SPEC                  64500021
*                                                                       64800021
         NI    UCBDMCT,ALLBITS-UCBMOUNT  SET MOUNT FLAG OFF             65100021
         TM    JFCBLTYP,JFCBAL          WERE ANSI LABEL SPEC.           65400021
         BNO   ETO14900                 NO, GO SET STD LAB IN UCB       65700021
         OI    UCBSTAB,UCBBSTR          SET ANSI VOL IND IN UCB         66000021
         CLI   VOLSEC,BLANK             VOL ACCESSIBILITY BLANK         66300021
         BNE   ETO15400                 NO, CAN'T USE THIS VOLUME       66600021
         B     ETO15000                 GO SET FSCT AND FSEQ            66900021
ETO14900 EQU   *                        SET STD LAB IND                 67200021
         NI    UCBSTAB,X'FF'-UCBBSTR    TURN OFF AL LABEL BIT           67500021
         OI    UCBSTAT,UCBDADI          SET STND LBL IND IN UCB         67800021
ETO15000 EQU   *                        SET FSCT AND FSEQ               68100021
*                                                                       68400021
         MVC   UCBVOLI,VOLSERNO         MOVE VOLUME SERIAL NUMBER READ  68700021
         MVC   DXVOLSR2,VOLSERNO        FROM LABEL TO UCB AND JFCB      69000021
*                                                                       69300021
*              LOAD THE TAPE OUTPUT HEADER LABEL MODULE                 69600021
*                                                                       69900021
         LA    R7,MOD2B1Z               SET R7 TO TTR                   70200021
ETO15100 SR    RET,RET                  ZERO RETURN CODE                70500021
         LA    RWTGC,DXXENTRY           SET R8 FOR RES RTN              70800021
         LA    RWTG,DXXAREA             POINT TO EOV WTG                71100021
         IECRES XCTL,(R7)               GO TO NEXT MODULE               71400021
ETO15200 EQU   *                                                        71700021
         OI    DXOPCLSW,HEX40           IND ENTRY TO NSLEHDRO           72000021
         NI    UCBDMCT,ALLBITS-UCBMOUNT  CLEAR MOUNT FLAG IN UCB        72300021
*                                                                       72600021
         MVC   DXXMODNM,NSLHDR          CHANGE TO NSLEHDRO              72900021
         MVI   DXCCW1,CCWREW            REWIND OP CODE                  73200021
         BAL   R8,ETO15500              REWIND                          73500021
         LR    R8,RES                   SAVE RES PTR                    73800021
         LR    RES,RDEB                 PUT DEB IN R5 FOR NSL           74100021
         B     ETO14300                 BR TO SETUP XCTL                74400021
*                                                                       74700021
ETO15300 EQU   *                                                        75000021
         LA    RWTGC,DXXENTRY           SET R8 FOR RES RTN              75300021
         LA    RWTG,DXXAREA             POINT TO EOV WTG                75600021
         DMABCOND 144,MODPD1Z           ABEND 637 I/O ERROR             75900021
*                                                                       76200021
*                                                                       76500021
*  THIS VOLUME HAS LIMITED ACCESSIBILY AND CAN'T BE USED                76800021
*  SET UP TO WRITE A MESSAGE TO THE OPERATOR                            77100021
*  THEN MOUNT A SCRATCH TAPE                                            77400021
*                                                                       77700021
ETO15400 EQU   *                        ACCESSIBILITY ERROR             78000021
         MVC   MSGLSTSZ(ANMSGL),ANMSG   SET UP ANSI SEC MSG             78300021
         MVC   MESSAGEA+K8(K8),TIOEDDNM  MOVE IN DD NAME                78600021
         MVC   MESSAGEA+K30(K6),UCBVOLI  MOVE IN SER NO                 78900021
         WTO   MF=(E,MSGLSTSZ)                                          79200021
         MVC   DXVOLSR2,SCRTCH2P        SET UP FOR                      79500021
*                                       DEMOUNT AND MOUNT SCRTCH        79800021
         LA    R7,MOD2N1Z               SET R7 TO TTR                   80100021
         B     ETO15100                 GO XCTL                         80400021
*              ENTER VIA BAL RH,EXECUTE                                 80700021
*                                                                       81000021
ETO15500 EQU   *                                                        81300021
         SPACE                                                          81600021
         BAL   RWTG,ETO15600            GO ISSUE EXCP AND WAIT          81900021
         SPACE                                                          82200021
         TM    DXECB,ECBNOERR           IO ERROR                        82500021
         BC    12,ETO15300              YES, BRANCH TO ABEND            82800021
         BR    R8                       RETURN                          83100021
         SPACE                                                          83400021
*              ENTER VIA BAL RWTG,EXEXCP                                83700021
         SPACE                                                          84000021
ETO15600 EQU   *                        PERFORM I/O                     84300021
         SPACE                                                          84600021
         EXCP  DXIOB                    ISSUE EXCP                      84900021
         SPACE                                                          85200021
         WAIT  ECB=DXECB                ISSUE WAIT                      85500021
         SPACE                                                          85800021
         BR    RWTG                     GO BACK TO MAIN LINE            86100021
         SPACE                                                          86400021
*                                                                       86700021
*                   CONSTANTS                                           87000021
         LTORG                                                          87300021
*                                                                       87600021
         DC    0F'0'                    ORG TO FULL WORD                87900021
NSLHDR   DC    C'NSLEHDRO'              CHARACTERS NSLEHDRO             88200021
NC802P   DC    X'0700000000000050'      REW & 80 BYTE LENGTH            88500021
SEN18P   DC    X'20000012'              SENSE 18 BYTES-SLI ON    XM3580 88800003
EMOD2P   DC    C'EMOD'                  HALF OF EMODVOL1-XCTL           89100021
         DC    C'VOL1'                  CHAR VOL1                       89400021
SCRTCH2P DC    C'SCRTCH'                SCRTCH VOL SER NO               89700021
ANMSG    WTO   'IEC017I DDNAME  ,ASCII VOLUME VOLSER NOT OPENED 1',    X90000021
               MF=L,DESC=4,ROUTCDE=(11)                                 90300021
ANMSGL   EQU   *-ANMSG                                                  90600021
*              XCTL TABLE                                               90900021
*                                                                       91200021
XCTLTA1Z DC    0D'0'                    ORG TO DOUBLE WORD              91500021
MOD2B1Z  DC    C'2B'                    ID OF VOL HEADER LABEL MOD      91800021
         DC    X'00000000'              TTRL                            92100021
MOD2N1Z  DC    C'2N'                    ID OF INVLD TAPE RECOVERY MOD   92400021
         DC    X'00000000'              TTRL                            92700021
MODPD1Z  DC    C'0P'                    PROB DETER. MOD ID              93000021
         DC    X'00000000'              TTRL                            93300021
         DC    X'0000'                  END OF TABLE MARKER             93600021
PATCHL1Z EQU   IFG0551Z+1020-*          CALC LENGTH OF PATCH AREA       93900021
PATCH1Z  DC    (PATCHL1Z)X'00'          ZERO PATCH AREA                 94200021
LOADID2P DC    C'055'                   EOV SVC CODE                    94500021
         DC    AL1((XCTLTA1Z-IFG0551Z)/8)  DBL WDS TO XCTL TABLE        94800021
         IECDSECS CVT,TCB,DCB,UCB,MAIN,DEB,TIOT,EXPAND=YES              95100021
         IECEQU                                                         95400021
         END                                                            95700021
