         TITLE 'ESD CARD PROCESSOR'                                     00100000
*FUNCTION/OPERATION: THIS MODULE PROCESSES THE ESD CARDS PRODUCED BY  * 00200000
*      ASSEMBLERS AND COMPILERS. IT ALSO PROCESSES THE ESD RECORDS    * 00300000
*      WHICH ARE THE OUTPUT OF A PREVIOUS LINK EDIT. AS EACH ESD ITEM * 00400000
*      IS ENCOUNTERED,IT IS ENTERED IN THE COMPOSITE ESD. IF THE      * 00500000
*      SYMBOL IS UNIQUE, THE ITEM IS ENTERED IN A NEW LINE, OTHERWISE * 00600000
*      THE HIERARCHIAL RULES OF ESD TYPES APPLY AND THE EXISTING      * 00700000
*      LINE IS MODIFIED. FOLLOWING ARE A FEW EXAMPLES OF COLLECTION.  * 00800000
*      SECTION DEFINITION + EXTERNAL REFERENCE = SECTION DEFINITION   * 00900000
*      LABEL DEFINITION + EXTERNAL REFERENCE = LABEL DEFINITION       * 01000000
*      EXTERNAL REFERENCE + EXTERNAL REFERENCE = EXTERNAL REFERENCE   * 01100000
*                                                                     * 01200000
*      PSEUDO REGISTERS MAY ONLY COLLECT PSEUDO REGISTERS,E.G.        * 01300000
*      A PR CANNOT COLLECT AVER BUT MAY ONLY COLLECT A PR .           * 01400000
*                                                                     * 01500000
*      IN THE PROCESS OF CREATING THE COMPOSITE ESD, THE ESD PROCESSOR* 01600000
*      ALSO CREATES THE RENUMBERING TABLE WHICH IS A TRANSLATION TABLE* 01700000
*      USED TO CHANGE ID'S FROM ESD-RELATIVE, TO CESD-RELATIVE.       * 01800000
*                                                                     * 01900000
*ENTRY POINTS  IEWLMESD - BEGINNING OF CSECT  -  LA  13,SAVEAREA      * 02000000
*                                                  BALR 14,15         * 02100000
*INPUT:                      -REGISTERS-                              * 02200000
*      REGISTER 4 - BYTE COUNT OF ESD ITEMS TO BE PROCESSED           * 02300000
*      REGISTER 5- ID OF FIRST ESD ITEM INPUT TO ESD PROCESSOR        * 02400000
*      REGISTER 6- ADDRESS OF FIRST ESD ITEM TO BE PROCESSED          * 02500000
*                            - OTHER INPUT -                          * 02600000
*      THE BASIC INPUT IS THE ESD RECORD ITSELF WHICH IS READ BY THE  * 02700000
*      INPUT PROCESSOR                                                * 02800000
*                                                                     * 02900000
*OUTPUT:  THE COMPOSITE EXTERNAL SYMBOL DICTIONARY(CESD)              * 03000000
*         THE RENUMBERING TABLE(RNT)                                  * 03100000
*           NEITHER OF THE ABOVE TABLES IS OUTPUT TO AN I/O DEVICE    * 03200000
*           BUT THEY ARE USED IN SUBSEQUENT PROCESSES                 * 03300000
*EXTERNAL ROUTINES: IEWLELOG- WRITES ERROR DIAGNOSTIC CODE            * 03400000
*          IEWLCDLK - DELINK ROUTINE - IF AN RLD ITEM REQUIRES A      * 03500000
*                     DELINK VALUE, THIS ROUTINE SAVES IT IN THE      * 03600000
*                     DELINK TABLE                                    * 03700000
*                     CALLING SEQUENCE - BALR 14,15                   * 03800000
*EXITS-NORMAL:  AFTER ALL ESD ITEMS INPUT HAVE BEEN PROCESSED,CONTROL * 03900000
*               RETURNS TO THE INPUT PROCESSOR VIA REGISTER 14        * 04000000
*EXITS-ERROR:   THERE ARE NO ERROR EXITS TO THE SYSTEM. ALL ERRORS    * 04100000
*               ARE RELAYED THROUGH THE ERROR DIAGNOSTIC ROUTINE      * 04200000
*               WHICH THEN DECIDES WHETHER TO PROCEED OR STOP         * 04300000
*                                                                     * 04400000
*TABLES/WORK AREAS: NO INTERNAL TABLES ARE USED                       * 04500000
*ATTRIBUTES: REUSABLE                                                 * 04600000
*NOTES: N/A                                                           * 04700000
IEWLMESD CSECT                                                          04800000
* 249100-249500,291000,292000,588000,589100-589900,652500        A22116 04820000
* 395000-397200                                                  A20632 04840000
* 564400-565600                                                  A22103 04860000
* 216200-216300                                                  A40594 04870021
* 465000,472000-473000                                           A26198 04880021
*A471300                                                         A44660 04886021
*D472500                                                         A44660 04892021
*A105000                                                        SA53762 04894021
*A294400-297000                                                 SA60214 04896021
*A32900,334000                                                  SA63255 04898021
*A596000                                                        SA61609 04898421
*C346000,I346000                                                SA65984 04898821
*C346000-346500,C346800,C346920,D346740                         SA69196 04899221
*C253000-255000,C461000,I461000                                 SA68823 04899621
        ENTRY IEWLCE30                                                  04900000
         ENTRY IEWLCTTY                                                 05000000
        ENTRY IEWLCRID                                                  05100000
SYSRET   EQU   14                                                       05200000
RNT      EQU   5                                                        05300000
TEMP2    EQU   4                                                        05400000
CESDCHN  EQU   14                                                       05500000
SD       EQU   X'00'                                                    05600000
NULL     EQU   X'07'                                                    05700000
CESDID   EQU   9                                                        05800000
CESDORG  EQU   9                                                        05900000
ESDORG   EQU   9                                                        06000000
CESDSEG  EQU   12                                                       06100000
RNTTYPE  EQU   3                                                        06200000
RNTFLAG  EQU   2                                                        06300000
CM       EQU   X'05'                                                    06400000
TEMP     EQU   10                                                       06500000
CESDLEN  EQU   13                                                       06600000
SYSBRNCH EQU   15                                                       06700000
ESDLEN   EQU   13                                                       06800000
CESDTYPE EQU   8                                                        06900000
CESDNAME EQU   0                                                        07000000
ESDNAME  EQU   0                                                        07100000
CESDTF   EQU   10                                                       07200000
CESDXR   EQU   7                                                        07300000
LABELDEF EQU   X'01'                                                    07400000
LD       EQU   X'01'                                                    07500000
PC       EQU   X'04'                                                    07600000
LR       EQU   X'03'                                                    07700000
INTERNAL EQU   13                                                       07800000
SUBTYPE  EQU   13                                                       07900000
ER       EQU   X'02'                                                    08000000
ESDSEG   EQU   12                                                       08100000
PR       EQU   X'06'                                                    08200000
ESDTYPE  EQU   8                                                        08300000
ESDADD   EQU   6                                                        08400000
APT      EQU   2                                                        08500000
CESD     EQU   3                                                        08600000
BASE     EQU   12                                                       08700000
AUTOLIB  EQU   X'40'                                                    08800000
ESDWRITE EQU   X'01'                                                    08900000
NOLENBIT EQU   X'40'                                                    09000000
TEMP1    EQU   8                                                        09100000
TEMP4    EQU   0                                                        09200000
TEMP3    EQU   1                                                        09300000
OVBIT    EQU   X'20'                                                    09400000
TBLONUM  EQU   X'10D'                                                   09500000
REGSAVE  EQU   76                                                       09600000
OBJCTMOD EQU   X'20'                                                    09700000
RETURN   EQU   11                                                       09800000
BYTECNT  EQU   4                                                        09900000
RNTID    EQU   0                                                        10000000
RNTR     EQU   4                                                        10100000
COM      EQU   X'04'                                                    10200000
ESDOVFLW EQU   X'419'                                                   10300000
RNTOFLOW EQU   X'41A'                                                   10400000
ERR23    EQU   X'317'                                           SA53762 10500021
WX       EQU   X'0A'               WXTERN ESD ITEM                II288 10550000
         USING IEWLMESD,BASE                                            10600000
         USING APTDSECT,APT   ESTABLISH ADDRESSABILITY FOR APT          10700000
         STM   SYSRET,BASE,12(INTERNAL) SAVE CALLERS REGISTERS          10800000
         LR    BASE,SYSBRNCH            BASE IN 12                      10900000
         BC    15,MODID+6              BRANCH AROUND MODULE IDENT       10930000
MODID    DC    C'01MESD'                                                10960000
         ST    INTERNAL,SAVEAREA        SAVE ADDRESS OF SAVEAREA        11000000
         ST    SYSRET,REG24SA                                           11100000
         TM    APT1,OBJCTMOD       IS INPUT OBJECT MODULE               11200000
         BC    1,ESD01                  NO BRANCH                       11300000
         CH    BYTECNT,C56              IS BYTE COUNT GR 56             11400000
         BC    2,BADCARDO               YES ERROR                       11500000
         BC    15,ESD02                                                 11600000
ESD01    CH    BYTECNT,C240             IS BYTE COUNT GR 240            11700000
         BC    2,BADCARDL               YES ERROR                       11800000
ESD02    SRL   BYTECNT,4                NUMBER OF ESD ITEMS             11900000
         LTR   BYTECNT,BYTECNT  IS BYTE COUNT LESS THAN 16 DECIMAL      12000000
         BC    8,BADCARDO    NO-CONTINUE--YEW--PRINT ERROR              12100000
         STM   BYTECNT,RNT,REGSA4                                       12200000
*              INITIALIZE ALL BASES AND INDEXES                         12300000
         L     RNT,RECNT           RENUMBERING TABLE BASE REGISTER      12400000
         L     CESD,CHESD          CESD BASE REGISTER                   12500000
*              EXTRACT BITS 5,6,7 OF TYPE AND MAKE IT A BYTEFULL        12600000
ESD1     MVC   TESTYPE(1),ESDTYPE(ESDADD)                               12700000
*              MOVE ESD TYPE TO INTERNAL WORK AREA                      12800000
         LR    CESDXR,CESD              SAFETY FOR IDCESD               12900000
         NI    ESDTYPE(ESDADD),X'1F'   CLEAR ALL FLAGS EXCEPT DELETE    13000000
         NI    TESTYPE,X'0F'       CLEAR DELETE BIT               II288 13100000
*              IS ESD TYPE PR                                           13200000
         TM    APT1,OBJCTMOD       IS INPUT OBJECT MODULE               13300000
         BC    1,ESD1A0                NO-BRANCH                        13400000
         NI    ESDTYPE(ESDADD),X'EF'   CLEAR DELETE BIT                 13500000
ESD1A0   CLI   TESTYPE,PR                                               13600000
         BC    8,ESD2                                                   13700000
*              YES-BRANCH TO ESD2 NOT TO DESTROY ALIGNMENT FIELD        13800000
*              NO-CONTINUE                                              13900000
         MVC   ESDSEG(1,ESDADD),CSNO+1                                  14000000
*              SET ESD SEGMENT NUMBER FIELD TO THE CURRENT SEGMENT      14100000
*              IF AUTOMATIC LIBRARY CALL IS IN OPERATION, THE CURRENT * 14200000
*              SEGMENT NUMBER IS ONE                                  * 14300000
         TM    APT1,AUTOLIB                                             14400000
         BC    8,ESD1A                                                  14500000
         MVI   ESDSEG(ESDADD),1                                         14600000
*              IS ESD TYPE AN ER                                      * 14700000
ESD1A    CLI   TESTYPE,ER          IS TYPE ER                           14740000
         BC    8,ESD1B             YES                            II288 14780000
         CLI   TESTYPE,WX          IS TYPE WX                     II288 14820000
         BC    7,ESD2              NO                             II288 14860000
*              NO-BRANCH TO ESD2                                        14900000
*              YES-CONTINUE                                             15000000
*              CLEAR BYTE 9 OF THE ER FOR AUTOMATIC LIBRARY CALL      * 15200000
ESD1B    XC    ESDORG(3,ESDADD),9(ESDADD)                         II288 15300000
         TM    APT1,OBJCTMOD                                            15400000
*              IS INPUT OBJECT MODULE                                   15500000
*              NO-BRANCH TO ESD2                                        15600000
*              YES-CONTINUE                                             15700000
*              ALL ERS  FROM OBJECT MODULES ARE PURE ERS(BYTE 13 = 0) * 15800000
         BC    1,ESD2                                                   15900000
         MVI   SUBTYPE(ESDADD),X'00'                                    16000000
ESD2     L     TEMP,RCCB                                                16100000
*              ARE THERE ANY REPLACE/CHANGE CARDS IN CHAIN            * 16200000
         LTR   TEMP,TEMP                                                16300000
         BC    8,ESD3                                                   16400000
*              YES-CONTINUE BY BRANCHING TO REPLACE/CHANGE CARD PROCESS 16500000
         L     INTERNAL,RPCHGADD                                        16600000
         BALR  RETURN,INTERNAL                                          16700000
*              REPLACE/CHANGE CARD PROCESSOR RETURNS HERE               16800000
ESD3     CLI   TESTYPE,PC                                               16900000
*              IS ESD TYPE PRIVATE CODE                                 17000000
*              YES-BRANCH TO ENTER PC AT CURRENT LINE + 1               17100000
*              NO-CONTINUE TESTING FOR LABEL DEFINITION                 17200000
         BC    8,ESD20                                                  17300000
         CLI   TESTYPE,NULL            IS TYPE A NULL                   17400000
         BC    8,RENUMBER              YES , BRANCH                     17500000
*              IS ESD TYPE LABEL DEFINITION                             17600000
         CLI   TESTYPE,LD                                               17700000
*              NO-BRANCH TO ESD4 TO SEARCH THE CESD                     17800000
*              YES-CHANGE TYPE TO LR AND SET LABEL DEFINITION BIT ON    17900000
         BC    7,ESD4                                                   18000000
         MVI   TESTYPE,LR                                               18100000
         OI    INTERN1,LABELDEF                                         18200000
ESD4     LR    CESDXR,CESD                                              18300000
*              INITIALIZE CESD LOOP                                     18400000
         LH    CESDTF,ENCDC                                             18500000
         LA    CESDTF,1(CESDTF)                                         18600000
ESD5     LA    CESDXR,16(CESDXR)                                        18700000
*              IS CESD LOOP DONE                                        18800000
         BCT   CESDTF,ESD6                                              18900000
*              YES-BRANCH TO NON-RESOLUTION PROCESSING                  19000000
         B     ESD23                                                    19100000
*              NO-CONTINUE CHECKING FOR A SYMBOL MATCH                  19200000
ESD6     CLC   ESDNAME(8,ESDADD),CESDNAME(CESDXR)                       19300000
*              DO ESD AND CESD SYMBOLS MATCH                            19400000
*              NO-CONTINE CESD SEARCH                                   19500000
         BC    7,ESD5                                                   19600000
*              YES-PERFORM COLLECTION OF ESD AND CESD TYPES             19700000
*              EXTRACT CESD TYPE FOR TESTING PURPOSES                   19800000
ESD6A    EQU   *                                                        19900000
         MVC   CESDTTYP(1),CESDTYPE(CESDXR)                             20000000
         NI    CESDTTYP,X'0F'                                     II288 20100000
         BAL   RETURN,IDCESD                                            20200000
         CLI   CESDTTYP,NULL                                            20300000
         BC    8,ESD5                                                   20400000
         CLI   TESTYPE,PR                                         II288 20500000
*              IS ESD TYPE PSEUDO REGISTER                              20600000
*              YES-A PSEUDO REGISTER MAY ONLY COLLECT ANOTHER           20700000
         BC    8,ESD9                                                   20800000
*              NO-THE CESD TYPE MAY BE A PSEUDO REGISTER                20900000
*              IS CESD TYPE PSEUDO REGISTER OR NULL                     21000000
         CLI   CESDTTYP,PR                                              21100000
*              YES-RETURN TO CESD SEARCH                                21200000
         BC    8,ESD5                                             II288 21250000
         CLI   CESDTTYP,NULL       IS TYPE NULL                   II288 21300000
         BC    8,ESD5                                                   21350000
*              NO-CONTINUE                                              21400000
*                                                                       21410000
*        PROCESS WX'S  HERE.  IF WX MATCHES ANYTHING BUT ANOTHER  II288 21420000
*        WX, CHANGE THE TYPE TO ER AND PROCESS NORMALLY.          II288 21430000
*                                                                 II288 21440000
         CLI   TESTYPE,WX          IS INPUT ESD TYPE WX           II288 21450000
         BC    7,ESD6B             NO - BRANCH                    II288 21460000
*        INPUT ITEM IS WX                                         II288 21470000
         CLI   CESDTTYP,WX         IS CESD A WX                   II288 21480000
         BC    7,ESD6C             NO - BRANCH                    II288 21490000
         B     RENUMBER            BOTH TYPES ARE WX              II288 21500000
*        ONLY  INPUT ITEM IS WX                                   II288 21510000
ESD6C    CLI   CESDTTYP,ER         IS CESD TYPE ER                II288 21520000
         BNE   ESD6D               NO                             II288 21530000
         CLI   SUBTYPE(CESDXR),X'80'  IS CESD ITEM A CONTROL CARD II288 21540000
         BC    2,ESD5              YES - CONTINUE CESD LOOP       II288 21550000
ESD6D    MVI   TESTYPE,ER          CHANGE INPUT ITME TO ER        II288 21560000
         MVI   ESDTYPE(ESDADD),ER                                 II288 21570000
         B     ESD7                CONTINUE                       II288 21580000
ESD6B    CLI   CESDTTYP,WX         IS CESD TYPE WX                II288 21590000
         BC    7,ESD7              NO - BRANCH                    II288 21600000
*        ONLY CESD TYPE IS WX - CHANGE TO ER                      II288 21610000
         NI    CESDTTYP,X'F7'          CHANGE CESD ITEM TO ER    A40594 21620021
         NI    CESDTYPE(CESDXR),X'F7'  CHANGE CESD ITEM TO ER    A40594 21630021
ESD7     TM    CESDTYPE(CESDXR),X'40' IS TYPE CHAIN               II288 21640000
*              YES-BRANCH TO RESET CESD INDEX TO CHAIN VALUE            21700000
         BC    1,ESD13                                                  21800000
*              IS CESD TYPE ER                                          21900000
         LA    RETURN,ESD23A                                            22000000
         CLI   CESDTTYP,ER                                              22100000
*              YES-SEE IF IT IS A CONTROL CARD                          22200000
         BC    8,ESD12                                                  22300000
*              IT IS NOT AN ER OR CONTROL CARD                          22400000
         CLI   TESTYPE,LR                                               22500000
*              IS ESD TYPE LR                                           22600000
         BC    7,ESD14                                                  22700000
*              NO-BRANCH FOR FURTHER EXAMINATION OF ESD TYPE            22800000
*              YES-PERFORM LABEL REFERENCE RESOLUTION                   22900000
         OI    INTERN1,X'02'                                            23000000
*              SET MATCH BIT ON INTERNALLY                              23100000
         BC    15,LABEL                                                 23200000
ESD9     CLI   CESDTYPE(CESDXR),PR                                      23300000
*              IS CESD TYPE A PSEUDO REGISTER                           23400000
         BC    7,ESD5                                                   23500000
*              NO-RETURN TO THE CESD SEARCH                             23600000
*              YES-BOTH ESD AND CESD TYPES ARE PSEUDO REGISTERS         23700000
         CLC   ESDLEN(3,ESDADD),CESDLEN(CESDXR)                         23800000
*              IS ESD LENGTH GREATER THAN CESD LENGTH                   23900000
*              NO-BRAN.H TO CHECK ALIGNMENT                             24000000
         BC    4,ESD10                                                  24100000
*              YES SET CESD LENGTH TO ESD LENGTH                        24200000
         MVC   CESDLEN(3,CESDXR),ESDLEN(ESDADD)                         24300000
ESD10    OC    CESDSEG(1,CESDXR),ESDSEG(ESDADD)                         24400000
*              SET CESD ALIGNMENT TO THE HIGHER OF THE TWO VALUES       24500000
         BC    15,RENUMBER                                              24600000
ESD12    CLI   SUBTYPE(CESDXR),X'80'                                    24700000
*              IS CESD SUBTYPE FOR A CONTROL CARD                       24800000
         BC    2,ESD5                                                   24900000
*              YES-CONTINUE CESD LOOP                                   25000000
*              NO-RESUME PROCESSING                                     25100000
         OI    INTERN1,MATCHER         SHOW WE MATCHED AN ER     A26198 25150021
*              IS ESD TYPE CM,SD,LR                                     25200000
         CLI   TESTYPE,X'02'           IS INPUT ITEM AN ER      SA68823 25250021
         BE    ESD120                  BRANCH IF SO             SA68823 25300021
         TM    TESTYPE,X'03'           IS INPUT ITEM AN LR      SA68823 25350021
         BNO   ESD17                   BRANCH IF NOT            SA68823 25400021
         TM    CESDORG(CESDXR),X'80'   TEST IF BLDL ISSUED      SA68823 25450021
         BNO   ESD17                   BRANCH IF NOT            SA68823 25500021
         L     TEMP,REGSA5             GET CESD ID OF ITEM      SA68823 25550021
         SLL   TEMP,2                  CALC RNT OFFSET          SA68823 25560021
         AR    TEMP,RNT                POINT TO RNT ENTRY       SA68823 25570021
         OI    RNTFLAG(TEMP),X'80'     SET BLDL ISSUED FLAG     SA68823 25580021
         B     ESD17                   CONTINUE TO CONVERT ER   SA68823 25590021
ESD120   EQU   *                                                SA68823 25592021
         TM    ESDTYPE(ESDADD),X'10'    IS INCOMING ITEM DELETE/REPLACE 25600000
         BC    8,ESD12A                 NO-BRANCH                       25700000
         TM    CESDTYPE(CESDXR),X'10'   IS CESD TYPE DELETE/RELPACE     25800000
         BC    8,ESD15A                 NO                              25900000
*                                       CESD ITEM IS ALSO DEL/REP       26000000
         TM    SUBTYPE(CESDXR),X'08'         IS IT A DELETE             26100000
         BC    8,ESD15A                 NO BRANCH                       26200000
         TM    SUBTYPE(ESDADD),X'08'    IS ESD TYPE A DELETE            26300000
         BC    8,CESDDLNK               NO BRANCH                       26400000
         BC    15,ESD23                 DELETE-DELETE CAUSES BOTH LINES 26500000
*                                       TO BE ENTERED                   26600000
ESD12A   TM    SUBTYPE(ESDADD),X'07'    IS SUBTYPE A PURE ER            26700000
         BC    5,ESD17                                                  26800000
         NI    SUBTYPE(CESDXR),X'F7'    CLEAR DELETE BIT MAKING SUBTYPE 26900000
*                                       A REPLACE                       27000000
         TM    SUBTYPE(CESDXR),X'06'    IS SUBTYPE A NO CALL            27100000
*                                       OR LIBR ARY MEMBER              27200000
         BC    9,RENUMBER               NO BRANCH                       27300000
         OI    SUBTYPE(CESDXR),X'01'    YES IT IS-MARK CESD MATCHED     27400000
         BC    15,RENUMBER                                              27500000
*              RESET CESD INDEX TO CHAIN VALUE AND THEN BRANCH BACK TO* 27600000
*              EXAMINE THE TYPE OF THE LINE TO WHICH THIS WAS CHAINED * 27700000
ESD13    LH    TEMP,CESDCHN(CESDXR)                                     27800000
         SLL   TEMP,4                                                   27900000
         LA    CESDXR,0(TEMP,CESD)                                      28000000
         BC    15,ESD6A                                                 28100000
ESD14    CLI   TESTYPE,SD                                               28200000
*              IS ESD TYPE SD                                           28300000
         BC    7,ESD18                                                  28400000
*              NO-BRANCH FOR FURTHER EXAMINATION OF ESD TYPE            28500000
*              YES-PERFORM SECTION DEFINITION RESOLUTION                28600000
         CLI   CESDTTYP,CM                                              28700000
*              IS CESD TYPE CM                                          28800000
         BC    7,ESD15                                                  28900000
*              NO-CONTINUE RESOLUTION                                   29000000
*        YES! COMPARE LENGTH FIELDS.CM SHOULD BE  SMALLER OR EQUAL.     29100000
*        IF IT'S NOT WE'LL GIVE ERROR MESSAGE AND TAKE CM LENGTH.222116 29200000
         CLC   ESDLEN(3,ESDADD),CESDLEN(CESDXR)                         29300000
         BNL   ESD38                                                    29400000
         CLC   ESDLEN(3,ESDADD),ZERO3  IS SD LENGTH ZERO?        A34230 29420021
         BNE   COMMON1                 GO TO HANDLE SD LESS     SA60214 29470021
ESD14A   LR    TEMP3,CESDXR            NAME OF COMMON FOR MSG    A34230 29750021
         LH    TEMP4,ERR57             ERR NUMBER,SEVERITY,DISP  A34230 29800021
         L     SYSBRNCH,ERDIG          ADDR. OF ERROR ROUTINE    A34230 29850021
         BALR  SYSRET,SYSBRNCH         GO TO PRINT MSG           A34230 29900021
         B     ESD38                   CONT. PROCESSING SD ITEM  A34230 29950021
*              BRANCH TO SECTION DEFINITION PROCESSING                  30000000
ESD15    CLI   CESDTTYP,LR                                              30100000
*              IS CESD TYPE LABEL REFERENCE                             30200000
         LA    RETURN,ESD15A                                            30300000
         BC    8,DBLDEF                                                 30400000
*              YES-BRANCH TO ERROR ROUTINE FOR DOUBLE LABEL DEFINITION  30500000
*              NO-CONTINUE                                              30600000
ESD15A   LA    RETURN,ENTER                                             30700000
*              BRANCH TO DELETE CHAIN ROUTINE FOR AUTOMATIC REPLACE   * 30800000
         BC    15,DELCHN                                                30900000
*              IF THE ESD TYPE IS NOT MARKED DELETE,RENUMBER IT       * 31000000
ESD16    TM    ESDTYPE(ESDADD),X'10'                                    31100000
         BC    8,RENUMBER                                               31200000
*              IT IS DELETE SO BRANCH TO DELETE CHAIN ROUTINE           31300000
         BC    15,ESD15A                                                31400000
*              IS SUBTYPE UNMATCHED LIBRARY MEMBER                      31500000
ESD17    OI    INTERN1,X'08'                                            31600000
         TM    8(CESDXR),X'10'         IS CESD DELETE                   31700000
         BC    1,CESDDLNK               DELINK IT                       31800000
ESD17A   TM    13(CESDXR),X'06'        IF CESD TYPE IS LIBRARY MEMBER   31900000
         BCR   9,RETURN                DECHAIN IT                       32000000
         TM    13(CESDXR),X'04'                                         32100000
         BCR   1,RETURN                                                 32200000
         L     SYSBRNCH,ADDDECHN                                        32300000
         BCR   15,SYSBRNCH                                              32400000
ESD18    CLI   TESTYPE,CM                                               32500000
*              IS ESDTYPE COMMON                                        32600000
         BC    7,ESD16                                                  32700000
*              NO-BRANCH FOR ER PROCESSING                            * 32800000
         CLI   CESDTTYP,PC        CHECK FOR MATCH OF BLANK PC   SA63255 32900021
*              IS CESD TYPE PC                                          33000000
         BC    8,ESD5                                                   33100000
*              YES-NO MATCH RESULTS                                     33200000
         LA    RETURN,ESD15A                                            33300000
         CLI   CESDTTYP,LR        CHECK FOR MATCH OF BLANK LR   SA63255 33400021
*              IS CESDTYPE A LABEL                                      33500000
         BC    8,DBLDEF                                                 33600000
*              YES-BRANCH TO ERROR FOR DOUBLE LABEL DEFINITION MESSAGE  33700000
*              SET ESD TYPE TO CESD TYPE                                33800000
*              SET ESD TYPE TO DELETE AND THEN BRANCH TO THE COMMON   * 33900000
*              ROUTINE                                                  34000000
         BC    15,COMMON                                                34100000
*                                                                     * 34200000
*                   UNMATCHED  PC AND SD PROCESSING BEGINS            * 34300000
*                             HERE                                    * 34400000
*                                                                     * 34500000
ESD20    BAL   RETURN,NXTLINE          GET NEXT ITEM IN CESD    SA69196 34600021
         NC    ESDLEN(3,ESDADD),ESDLEN(ESDADD)                  SA65984 34660021
*              CHECK FOR LENGTH OF ZERO                         SA65984 34670021
         BNZ   ESD21                   SKIP IF NOT      SA65984,SA69196 34680021
         OI    TESTYPE,DELETE          MARK FOR DELETE IF SO    SA65984 34690021
         B     ENTER                 ENTER IN CESD, RNT SA65984,SA69196 34692021
ESD21    TM    APT1,AUTOLIB                                             34700000
*              IS AUTOMATIC LIBRARY CALL IN OPERATION                 * 34800000
         BC    8,ESD22                                                  34900000
*              NO-BRANCH AROUND                                         35000000
*              YES-SET BIT 0 OF TYPE TO A ONE                           35100000
         OI    ESDTYPE(ESDADD),X'80'                                    35200000
ESD22    OI    APT1,ESDWRITE                                            35300000
*              SET ESD WRITE INDICATOR ON                               35400000
*              IS LENGTH FIELD IN ESD BLANKS                            35500000
         NC    ESDLEN(3,ESDADD),ESDLEN(ESDADD)                          35600000
         BC    4,ENTER                                                  35700000
*              NO-ENTER THE LINE IN THE CESD                            35800000
*              YES-IS NO LENGTH BIT ON                                  35900000
         TM    APT2,NOLENBIT                                            36000000
*              YES-IGNORE IT                                          * 36100000
         BC    1,ENTER                                                  36200000
         OI    APT2,NOLENBIT                                            36300000
*              SET NOLENGTH BIT ON AND SAVE THE LINE ADDRESS IN APT   * 36400000
         ST    CESDXR,PDSE18                                            36500000
         BC    15,ENTER                                                 36600000
**********            NON RESOLUTION PROCESSING BEGINS HERE  ********** 36700000
ESD23    BAL   RETURN,FREELINE                                          36800000
*              SET CESD INDEX TO CURRENT LINE+1 AND UPDATE CURRENT CNT* 36900000
ESD23A   CLI   TESTYPE,LR                                               37000000
*              IS ESD TYPE LR                                           37100000
         BC    8,LABEL                                                  37200000
*              YES BRANCH TO LABEL ROUTINE                              37300000
*              NO-IS ESD TYPE SECTION DEFINITION                        37400000
         CLI   TESTYPE,SD                                               37500000
         BC    8,ESD21                                                  37600000
*              YES-BRANCH TO SECTION DEFINITION PROCESSING              37700000
*              NO-IS TYPE NULL                                          37800000
         CLI   TESTYPE,CM                                               37900000
*              SET INTERNAL COMMON INDICATOR ON AND MARK COMMON DELETE* 38000000
         BC    8,ESD42                                                  38100000
*              YES-BRANCH TO RENUMBER ROUTINE                           38200000
**********            THE ENTER ROUTINE STARTS HERE          ********** 38300000
ENTER    CH    CESDID,ENCDX                                             38400000
*              IS THE CESD LIMIT EXCEEDED                               38500000
         BC    2,ESDOFLOW                                               38600000
*              YES, BRANCH TO ERROR DIAGNOSTIC FOR CESD OVERFLOW MSG  * 38700000
*              NO-SET ESD SYMBOL AND ORIGIN INTO CESD LINE              38800000
         MVC   CESDNAME(8,CESDXR),ESDNAME(ESDADD)                       38900000
*              MOVE SYMBOL FIELD                                      * 39000000
         MVC   CESDORG(3,CESDXR),ESDORG(ESDADD)                         39100000
*              MOVE ORIGIN FIELD                                      * 39200000
         TM    CESDTYPE(CESDXR),X'20'                                   39300000
*              IS CESD TYPE INSERT                                      39400000
         BC     8,ESD24X         NO,  BRANCH.                    A20632 39480000
         CLI    TESTYPE,LR       IS ITEM AN LR                   A20632 39560000
         BC     7,ESD24          NO,  BRANCH.                    A20632 39640000
ESD24X   MVC    CESDSEG(1,CESDXR),ESDSEG(ESDADD)                 A20632 39720000
ESD24    MVC   CESDLEN(3,CESDXR),ESDLEN(ESDADD)                         39800000
*              SET CESD LENGTH FIELD TO ESD LENGTH FIELD                39900000
*              SET CESD TYPE TO ESD TYPE                                40000000
         NI    CESDTYPE(CESDXR),X'F0'   CLEAR LOW ORDER BITS      II288 40100000
         OC    CESDTYPE(1,CESDXR),TESTYPE                               40200000
         MVC   CLRBYT(1),ESDTYPE(ESDADD)                                40300000
         NI    CLRBYT,X'F0'        CLEAR BITS                     II288 40400000
         OC    CESDTYPE(1,CESDXR),CLRBYT                                40500000
**********            THE RENUMBER ROUTINE STARTS HERE       ********** 40600000
*              IF THE LINE WHICH IS ABOUT TO BE ENTERED IS AN LD        40700000
*              IT IS NOT ENTERED-ALL OTHERS ARE                         40800000
RENUMBER TM    INTERN1,LABELDEF                                         40900000
         BC    1,ESD30                                                  41000000
         L     TEMP,REGSA5                                              41100000
         LTR   TEMP,TEMP                                                41200000
         BC    12,TBLOFLOW                                              41300000
         CH    TEMP,ENCDX                                               41400000
         BC    2,TBLOFLOW                                               41500000
*              IF THE ENTRY WONT FIT IN THE RENUMBERING TABLE-          41600000
*              BRANCH TO ERROR DIAGNOSTIC FOR TABLE OVERFLOW MESSAGE    41700000
         SLL   TEMP,2                                                   41800000
*              COMPUTE ADDRESS OF RNT LINE                            * 41900000
         AR    TEMP,RNT                                                 42000000
         MVC   RNTTYPE(1,TEMP),TESTYPE                                  42100000
         MVC   CLRBYT(1),ESDTYPE(ESDADD)                                42200000
         NI    CLRBYT,X'F0'        CLEAR BITS                     II288 42300000
         OC    RNTTYPE(1,TEMP),CLRBYT                                   42400000
*              SET TYPE IN RNT                                          42500000
         OI    RNTFLAG(TEMP),X'01'                                      42600000
*              SET PRESENT FLAG ON IN RNT LINE AND THEN GO TO  IDCESD * 42700000
*              TO COMPUTE THE ID(LINE NUMBER) OF THE PRESENT LINE     * 42800000
         BAL   RETURN,IDCESD                                            42900000
         LH    TEMP1,RNTID(TEMP)                                        43000000
         STH   CESDID,RNTID(TEMP)                                       43100000
*              STORE THE LINE ID IN THE RNT                           * 43200000
         TM    RNTFLAG(TEMP),X'02'                                      43300000
*              IS DEPEND FLAG ON                                        43400000
         BC    8,ESD29                                                  43500000
*              NO-BRANCH TO UPDATE RNT INDEX                          * 43600000
*              YES-CLEAR DEPEND BIT IN RNT                            * 43700000
         NI    RNTFLAG(TEMP),X'FD'                                      43800000
ESD24A   SLL   TEMP1,4                                                  43900000
         AR    TEMP1,CESD               TEMP1 IS INDEX TO LABEL LINE    44000000
         TM    CESDTYPE(TEMP1),X'40'                                    44100000
         BC    8,ESD25                                                  44200000
*              IF THE CESD TYPE IS CHAINED A DOUBLE DEFINITION WILL     44300000
*              OCCUR IF THE PRESENTESD IS NOT MARKED DELETE           * 44400000
         TM    ESDTYPE(ESDADD),X'10'                                    44500000
         BC    1,ESD28B                                                 44600000
         LA    RETURN,ESD28B                                            44700000
*              BRANCH TO ERROR DIAGNOSTIC FOR DOUBLE SYMBOL DEFINITION* 44800000
*                        *****ERROR*****                              * 44900000
*                                                                     * 45000000
         BC    15,DBLDEF1                                               45100000
ESD25    TM    ESDTYPE(ESDADD),X'10'                                    45200000
         BC    1,ESD27                                                  45300000
*              IF ESD TYPE IS NOT DELETE - RENUMBER ID                  45400000
ESD26    LH    TEMP,12(TEMP1)                                           45500000
ESD26A   STH   CESDID,14(TEMP1)                                         45600000
*              IF CHAIN ENDS (TEMP= 0 ) STOP RENUMBERING LABELS       * 45700000
ESD26B   LTR   TEMP1,TEMP                                               45800000
         BC    8,ESD29                                                  45900000
         BC    15,ESD24A                                                46000000
ESD27    LH    TEMP2,14(,TEMP1)        GET CESD ID FOR SD ITEM  SA68823 46100021
         SLL   TEMP2,2                 CALC RNT OFFSET          SA68823 46120021
         AR    TEMP2,RNT               POINT TO RNT ENTRY       SA68823 46130021
         TM    RNTFLAG(TEMP2),X'80'    TEST FOR BLDL ISSUED FLG SA68823 46140021
         BNO   ESD27A                  BRANCH IF NOT ON         SA68823 46142021
         XC    CESDORG(3,TEMP1),CESDORG(TEMP1)                  SA68823X46144021
                                       CLEAR CESD FIELD         SA68823 46146021
         OI    CESDORG(TEMP1),X'80'    TRANSFER BLDL ISSUED FLG SA68823 46148021
         SR    TEMP2,TEMP2             CLEAR WORK REG           SA68823 46148421
         BCTR  TEMP2,0                 GET MAX CESD ID          SA68823 46148821
         B     ESD27B                  GO TO CONVERT CESD ITEM  SA68823 46149221
ESD27A   LH    TEMP2,14(,TEMP1)        RESTORE CESD ID OF SD    SA68823 46149621
ESD27B   EQU   *                                                SA68823 46149721
         MVI   CESDTYPE(TEMP1),ER      SET CESD TO ER            A26198 46150021
*              IF THE ESD TYPE IS DELETE, CHECK RNT POINTER TO SEE IF * 46200000
*              IT IS AN LD-IF IT IS SET TYPE TO ER MARKED DELETE      * 46300000
         LTR   TEMP2,TEMP2                                              46400000
         BZ    ESD28A                  LD THAT CAN BE DELETED    A26198 46460021
         BM    ESD28B                  LD THAT CAN'T BE DELETED  A26198 46520021
*              IF IT IS AN LR- THE RNT TYPE MUST BE SET TO ER DELETE  * 46600000
*              AS WELL AS CESD TYPE                                   * 46700000
ESD28    SLL   TEMP2,2                                                  46800000
         AR    TEMP2,RNT                                                46900000
*              SET RNT TYPE                                           * 47000000
*              SET CESD TYPE                                          * 47100000
         MVI   RNTTYPE(TEMP2),ER       RNT TYPE ER               A26198 47130021
         OI    RNTTYPE(TEMP2),DELETE   TURN ON DELETE FLAG       A44660 47140021
         TM    RNTFLAG(TEMP2),NODELETE   SHOULD WE MARK IT       A26198 47160021
*                                             FOR DELETION?      A26198 47190021
         BO    ESD28B                  NO,BRANCH                 A26198 47220021
ESD28A   OI    CESDTYPE(TEMP1),DELETE  YES, SET DELETE FLAG      A26198 47280021
*                                              IN TYPE           A26198 47310021
ESD28B   LH    TEMP,12(TEMP1)                                           47400000
*              SET SUBTYPE TO DELETE                                  * 47500000
         MVI   SUBTYPE(TEMP1),X'08'                                     47600000
         BC    15,ESD26B                TO CHECK IF CHAIN IS DONE       47700000
ESD29    L     TEMP,REGSA5                                              47800000
*              IF THE ITEM BEING PROCESSED IS COMMON-DELINK IT        * 47900000
         TM    INTERN1,COM                                              48000000
         BC    1,ESD43                                                  48100000
ESD29A   LA    TEMP,1(TEMP)                                             48200000
         ST    TEMP,REGSA5                                              48300000
IEWLCE30 EQU   *                                                        48400000
ESD30    NI    INTERN1,X'00'                                            48500000
         LA    ESDADD,16(ESDADD)                                        48600000
         L     TEMP,REGSA4                                              48700000
         BCT   TEMP,ESD30A                                              48800000
*              IF THE ESD CARD IS DONE- RETURN TO THE INPUT PROCESSOR * 48900000
ESD30A0  L     INTERNAL,SAVEAREA                                        49000000
         LM    SYSBRNCH,TEMP3,16(INTERNAL)                              49100000
         L     SYSRET,REG24SA                                           49200000
         LM    CESD,BASE,32(INTERNAL)                                   49300000
*              CLEAR INTERNAL INDICATORS                              * 49400000
         BCR   15,SYSRET                                                49500000
*              OTHERWISE SAVE THE RNTID AND RETURN TO THE BEGINNING   * 49600000
ESD30A   ST    TEMP,REGSA4                                              49700000
         BC    15,ESD1                                                  49800000
**********            THE LABEL ROUTINE STARTS HERE          ********** 49900000
LABEL    LH    TEMP,14(ESDADD)                                          50000000
*              COMPUTE THE RNT ADDRESS FOR THE LABEL ID               * 50100000
         SLL   TEMP,2                                                   50200000
         AR    TEMP,RNT                                                 50300000
         LA    INTERNAL,ENTER                                           50400000
         L     TEMP2,REGSA5                                             50500000
         TM    INTERN1,MATCHER         DID THIS MATCH AN ER?     A26198 50509021
         BNO   REN1                    NO, BRANCH                A26198 50518021
         TM    INTERN1,LABELDEF        IS THIS AN LD?            A26198 50527021
         BO    REN1                    YES, NO FLAG IN RNT       A26198 50536021
         SLL   TEMP2,2                                           A26198 50545021
         AR    TEMP2,RNT               ADD TO FORM RNT ADDRESS   A26198 50554021
         OI    RNTFLAG(TEMP2),NODELETE   YES,SET FLAG ON IN RNT  A26198 50563021
*                                      SO THIS CAN'T BE DELETED  A26198 50572021
         L     TEMP2,REGSA5            RESTORE RNT ID            A26198 50581021
REN1     EQU   *                                                 A26198 50590021
*              SAVE THE RNT ID FIELD                                  * 50600000
         LH    TEMP1,0(TEMP)                                            50700000
*              IS CONTROL SECTION PRESENT                               50800000
         TM    2(TEMP),X'01'                                            50900000
         BC    8,ESD33                                                  51000000
*              NO-BRANCH                                                51100000
*              IF RNT TYPE IS DELETE-BRANCH                             51200000
         TM    3(TEMP),X'50'                                            51300000
         BC    5,ESD31                                                  51400000
*              IF MATCH BIT IS ON-BRANCH                                51500000
         TM    INTERN1,X'02'                                            51600000
         BC    1,ESD32                                                  51700000
*              IF NOT-RENUMBER ID FIELD                                 51800000
         STH   TEMP1,14(ESDADD)                                         51900000
         BCR   15,INTERNAL                                              52000000
*              IF THE RNT TYPE IS DELETE -                              52100000
ESD32    BAL   RETURN,DBLDEF                                            52200000
ESD31    TM    INTERN1,LABELDEF                                         52300000
         BC    1,ESD44                                                  52400000
*              AND THE ESD TYPE IS LD - DONT ENTER THE LINE             52500000
*              IF IT IS AN LR -                                       * 52600000
         MVI   SUBTYPE(ESDADD),X'08'                                    52700000
         MVI   TESTYPE,2                                                52800000
         OI    ESDTYPE(ESDADD),X'10'                                    52900000
*              MAKE ESD TYPE ER MARKED DELETE                           53000000
         TM    INTERN1,X'0A'                                            53100000
*              IF IT IS A MATCHING SYMBOL, BRANCH TO  DELETE CHAIN    * 53200000
*              ROUTINE. IF NOT, STORE RNTID IN  BYTE 14 OF CESD LINE  * 53300000
         BC    8,ESD33A                                                 53400000
         BAL   RETURN,DELCHN                                            53500000
         BCR   15,INTERNAL                                              53600000
*                                                                       53700000
ESD33    OI    2(TEMP),X'02'                                            53800000
*              SET DEPENDENCY BIT ON IN RNT LINE FOR SD                 53900000
         TM    INTERN1,X'02'                                            54000000
*              IF IT IS A MATCHING SYMBOL - BRANCH, IF NOT- SET UP    * 54100000
*              CHAIN OF LABELS                                        * 54200000
         BC    1,ESD35                                                  54300000
         STH   CESDID,0(TEMP)                                           54400000
         STH   TEMP1,12(ESDADD)                                         54500000
         TM    INTERN1,X'01'                                            54600000
         BC    8,ESD33A                                                 54700000
         SR    TEMP2,TEMP2              CLEAR TEMP2                     54800000
         TM    INTERN1,MATCHER         DID THIS MATCH AN ER?     A26198 54820021
         BNO   ESD33A                  NO, BRANCH                A26198 54840021
         O     TEMP2,FS                YES, IT CAN'T BE DELETED  A26198 54860021
*              IF IT IS AN LD, BRANCH- OTHERWISE STORE INDEX TO RNT   * 54900000
*              LABEL LINE IN BYTES 12,13 OF LABEL ITEM                * 55000000
ESD33A   STH   TEMP2,14(ESDADD)                                         55100000
         BCR   15,INTERNAL                                              55200000
ESD35    BAL   RETURN,DELCHN                                            55300000
         MVI   TESTYPE,2                                                55400000
*              MAKE LABEL AN ER  AND CHAIN IT TO THE MATCH            * 55500000
         STH   CESDID,0(TEMP)                                           55600000
         STH   TEMP1,12(ESDADD)                                         55700000
         BCR   15,INTERNAL                                              55800000
**********            THE DELCHN ROUTINE STARTS HERE         ********** 55900000
DELCHN   STH   CESDID,14(ESDADD)                                        56000000
*              STORE THE ID OF THE LINE IT IS CHAINED TO IN BYTES 14- * 56100000
*              15 OF THE LINE AND MARK TYPE DELETE-CHAIN              * 56200000
         OI    ESDTYPE(ESDADD),X'50'                                    56300000
**********            THE FREELINE ROUTINE STARTS HERE       ********** 56400000
FREELINE CLI   TESTYPE,PR     IS THIS ESD ITEM A PSEUDO REGISTER A22103 56440000
         BE    NXTLINE    IF PSEUDO-REG USE NEW CESD LINE        A22103 56480000
* PSEUDO REGISTERS MUST BE IN THE ORDER OF APPEARANCE            A22103 56520000
         L     CESDXR,FLCD                                       A22103 56560000
         LTR   CESDXR,CESDXR                                            56600000
*              IF THERE ARE NO LINES IN THE ENTRIES DELETED CHAIN,    * 56700000
*              GO TO NXTLINE TO SELECT CURRENT LINE+1                 * 56800000
         BC    8,NXTLINE                                                56900000
ESD37    L     TEMP3,12(CESDXR)                                         57000000
*              SET FIRST FREE LINE TO NEXT FREE LINE                  * 57100000
         ST    TEMP3,FLCD                                               57200000
*              IDCESD COMPUTES AN ID OF A CESD LINE GIVEN  AN ADDRESS * 57300000
IDCESD   LR    CESDID,CESDXR                                            57400000
         SR    CESDID,CESD                                              57500000
         SRL   CESDID,4                                                 57600000
         BCR   15,RETURN                                                57700000
*              NXTLINE INCREMENTS THE CURRENT CESD COUNT AND THEN     * 57800000
*              COMPUTES THE ADDRESS OF THE LINE(CESDXR)               * 57900000
NXTLINE  LH    CESDID,ENCDC                                             58000000
         LA    CESDID,1(CESDID)                                         58100000
         STH   CESDID,ENCDC                                             58200000
         LR    CESDXR,CESDID                                            58300000
         SLL   CESDXR,4                                                 58400000
         AR    CESDXR,CESD                                              58500000
         BCR   15,RETURN                                                58600000
COMMON   CLC   13(3,CESDXR),13(ESDADD)                                  58700000
*        IF CESD SIZE IS LESS,CHECK FOR SD TYPE CESD             A22116 58800000
         BNL   ESD38                                                    58850000
         TM    CESDTYPE(CESDXR),X'0F'  IS CESD SD                A22116 58910000
         BZ    COMMON1                                                  58916000
         MVC   13(3,CESDXR),13(ESDADD)                                  58922000
         B   ESD38                                                      58928000
COMMON1  LR    TEMP3,CESDXR                                             58934000
*                                 NAME OF COMMON.                A22116 58940000
         LH    TEMP4,CMGTSD       GET ERROR CODE                 A22116 58950000
         L     SYSBRNCH,ERDIG     GIVE ERROR MESSAGE             A22116 58960000
         BALR  14,15                                             A22116 58970000
*              IF OVERLAY-PROMOTION TAKES PLACE IN COMMON PATH        * 59100000
ESD38    TM    PDSE7,OVBIT                                              59200000
         BCR   8,RETURN                                                 59300000
         TM    CESDTYPE(CESDXR),X'20'    IS INSERT BIT ON IN CESD       59330000
         BCR   1,RETURN                 YES. USE CESD SEG NO            59360000
         L     INTERNAL,ADDCPTH                                         59400000
         BCR   15,INTERNAL                                              59500000
DBLDEF1  LR    TEMP3,TEMP1        POINT TO DUPLICATE NAME       SA61609 59600021
         BC    15,ESD39                                                 59700000
DBLDEF   LR    TEMP3,ESDADD                                             59800000
ESD39    EQU   *                                                        59900000
         LH    TEMP4,DLDEF                                              60000000
ESD39A   L     SYSBRNCH,ERDIG                                           60100000
         BALR  14,15                                                    60200000
         BCR   15,RETURN                                                60300000
TBLOFLOW LA    TEMP4,RNTOFLOW                                           60400000
         BC    15,ESD39A                                                60500000
ESDOFLOW LA    TEMP4,ESDOVFLW                                           60600000
         BC    15,ESD39A                                                60700000
**********            THE CESDDLNK ROUTINE STARTS HERE       ********** 60800000
CESDDLNK LH    RNTR,14(CESDXR)          LOAD WITH RNT POINTER           60900000
DLNK1    LR    TEMP3,CESDID                                             61000000
         L     SYSBRNCH,DELNKRT                                         61100000
         BALR  SYSRET,SYSBRNCH                                          61200000
         BCR   15,RETURN                                                61300000
INTERN1  DC    X'00'                                                    61400000
MATCHER  EQU   X'10'                   INTERN1 FLAG -- THIS      A26198 61410021
*                                      ENTRY MATCHED AN ER       A26198 61420021
NODELETE EQU   X'20'                   RNT FLAG -- THIS NAME     A26198 61430021
*                                      SHOULDN'T BE DELETED      A26198 61440021
DELETE   EQU   X'10'                   CESD TYPE DELETE FLAG     A26198 61450021
FS       DS    0F                                                A26198 61460021
         DC    X'FFFFFFFF'             NEG FULLWORD FOR LD CHAIN A26198 61470021
IEWLCTTY EQU   *                                                        61500000
TESTYPE  DC    X'00'                                                    61600000
CESDTTYP DC    X'00'                                                    61700000
ERR57    DC    X'2239'                 MSG NUMBER FOR MSG#562    A34230 61730021
ZERO3    DC    X'000000'               FOR CHECKING SD LENGTH    A34230 61760021
ADDCPTH  DC    V(IEWLCPTH)                                              61800000
ADDDECHN DC    V(IEWLCDCN)                                              61900000
RPCHGADD DC    V(IEWLMRCG)                                              62000000
DELNKRT  DC    V(IEWLCDLK)                                              62100000
ESD42    OI    INTERN1,COM                                              62200000
*              SET INTERNAL COMMON BIT ON AND MAKE ESD TYPE DELETE    * 62300000
         OI    ESDTYPE(ESDADD),X'10'                                    62400000
         BC    15,ENTER                                                 62500000
ESD43    LR    RNTR,TEMP                                                62600000
         LA    RETURN,ESD29A                                            62700000
*              CLEAR COMMON BIT AND SET UP FOR DELINKING              * 62800000
         NI    INTERN1,X'FB'                                            62900000
         OI    APT1,ESDWRITE                                            63000000
         BC    15,DLNK1                                                 63100000
ESD44    TM    INTERN1,X'0A'                                            63200000
         BC    4,ESD30                                                  63300000
         MVI   8(CESDXR),NULL                                           63400000
         BC    15,ESD30                                                 63500000
BADCARDO LA    TEMP3,0(0,ESDADD)                                        63600000
         SH    TEMP3,C16                                                63700000
         LH    TEMP4,ERR22                                              63800000
         BC    15,BADCRDL1                                              63900000
BADCARDL LA    TEMP4,ERR23                                              64000000
BADCRDL1 LA    RETURN,ESD30A0                                           64100000
         BC    15,ESD39A                                                64200000
REGSA4   DC    F'0'                                                     64300000
IEWLCRID EQU   *                                                        64400000
REGSA5   DC    F'0'                                                     64500000
REG24SA  DC    F'0'                                                     64600000
C56      DC    H'56'                                                    64700000
C240     DC    H'240'                                                   64800000
C16      DC    H'16'                                                    64900000
ERR22    DC   X'1216'                                                   65000000
DLDEF    DC    X'2118'                                                  65100000
SAVEAREA DC    F'0'                                                     65200000
CMGTSD   DC    X'2237'                                           A22116 65250000
CLRBYT   DC    X'00'                                                    65300000
         IEWAPT                                                         65400000
         END                                                            65500000
