*                                                                       00100013
*        PLINE AND PPOINT ARE ENTERED FROM DIRECTOR PART 2 WITH THE     00200013
*        ADDRESS OF A WORK AREA IN REGISTER 1.  THE FIRST WORD OF THE   00300013
*        WORK AREA CONTAINS THE ADDRESS OF THE PARAMETER LIST BELOW.    00400013
*                                                                       00500013
*                             PLINE AND PPOINT                          00600013
*                                                                       00700013
*                             INPUT PARAMETER LIST                      00800013
*                                                                       00900013
*                             +0  A(GDSVAR)                             01000013
*                             +4  A(X-COORD)                            01100013
*                             +8  A(Y-COORD)                            01200013
*                             +12 A(CORVAL)                             01300013
*                             +16 A(KEY)                                01400013
*                             +20 A(GENCODE)                            01500013
*                             +24 A(COUNT)                              01600013
*                             +28 A(X-INDEX)                            01700013
*                             +32 A(Y-INDEX)                            01800013
*                             +36 A(X-INCR)                             01900013
*                             +40 A(Y-INCR)                             02000013
*                                                                       02100013
*        EXTERNAL ROUTINES CALLED:                                      02200013
*                                                                       02300013
*        SCALE-IFFAHA06                                                 02400013
*        SCISSOR-IFFAHA07                                               02500013
*        KEY TABLE MANAGEMENT- IFFAHA03                                 02600013
*        DATA GENERATOR-IFFAHA04                                        02700013
*        UPDATE-IFFAHA13 AND IFFAHA14                                   02800013
*        EXTERNAL MACROS USED:                                          02900013
*                                                                       03000013
*        LINK                                                           03100013
*                                                                       03200013
         EJECT                                                          03300013
*        PLINE AND PPOINT WILL SPEND A GOOD PORTION OF ITS TIME         03400013
*        BUILDING A PARAMETER LIST WHICH IS USED AS THE INPUT           03500013
*        PARAMETER LIST TO SCALE, SCISSOR, DATA GENERATOR, AND          03600013
*        UPDATE.                                                        03700013
*                                                                       03800013
*        WORD 0 IS THE KEY WHICH IS RETURNED TO THE USER.  THE FIRST    03900013
*        HALFWORD CONTAINS THE LENGTH OF THE ELEMENT AND THE SECOND     04000013
*        HALFWORD CONTAINS THE LOGICAL START ADDRESS OF THE ELEMENT.    04100013
*                                                                       04200013
*        WORD 1 CONTAINS BIT SWITCHES.                                  04300013
*        BIT 0: 0=SINGLE ENTRY/1=MULTIPLE ENTRY                         04400013
*        BIT 1: INITIALIZED TO ZERO.  SET BY DATA GEN TO SHOW IF        04500013
*        FOR A SINGLE ENTRY IF THE DATA CONTAINS A SET MODE ORDER.      04600013
*        BITS 2,3,4:                                                    04700013
*        000 IS VECTOR INPUT                                            04800013
*        010 IS POINT INPUT                                             04900013
*        BIT 5: 0=OMIT/1=INCLUDE                                        05000013
*        BITS 6&7:                                                      05100013
*        00 IS ABSOLUTE OUTPUT                                          05200013
*        01 IS INCREMENTAL OUTPUT                                       05300013
*        11 IS OPTIMIZED OUTPUT                                         05400013
*        BITS 8-15: ARE RESERVED AND INITIALIZED TO ZERO. DATA          05500013
*        GEN WILL PLACE THE BYTE OF DATA CONTAINING THE BEAM BIT        05600013
*        HERE IF IT IS A SINGLE ENTRY WHICH IS KEYED OR CORRELATED.     05700013
*        BITS 16&17:                                                    05800013
*        00 IS FIRST PASS                                               05900013
*        01 IS NOT FIRST PASS, NOT LAST PASS                            06000013
*        11 IS LAST PASS                                                06100013
*        FOR SINGLE ELEMENTS THIS IS SET TO FIRST PASS.                 06200013
*        BIT 18: 0=DATA NOT KEYED/1=DATA KEYED                          06300013
*        BIT 19: 0=DATA NOT CORRELATED/1=DATA CORRELATED                06400013
*        BIT 20: 0=BEAM OFF/1=BEAM ON                                   06500013
*        BIT 21: 0=REPOSITION/1=NO REPOSITIONING                        06600013
*        BITS 22&23: RESERVED AND SET TO ZERO                           06700013
*        BIT 24: 0=NOT PART OF A SUBROUTINE/1:PART OF A SUBROUTINE      06800013
*        BIT 25: 0=NOT PART OF A SEQUENCE/1=PART OF A SWQUEN            06900013
*        BIT 25: 0=NOT PART OF A SEQUENCE/1=PART OF A SEQUENCE          07000013
*        BITS26-31: RESERVED AND SET TO ZERO                            07100013
*                                                                       07200013
*                                                                       07300013
*                                                                       07400013
         EJECT                                                          07500013
*        WORD 2 CONTAINS THE CORVAL                                     07600013
*                                                                       07700013
*        WORD 3 CONTAINS THE ADDRESS OF THE KEY.                        07800013
*                                                                       07900013
*        WORD 4 CONTAINS THE ADDRESS OF THE GDSCB.                      08000013
*                                                                       08100013
*        WORDS5,6,7&8: ARE SET TO ZERO AND IF A POSITIONING             08200013
*        VECTOR IS REQUIRED BECAUSE OF PREVIOUS SCISSORING, SCISSOR     08300013
*        WILL FILL THE FIELDS IN WITH X ABSOLUTE, Y ABSOLUTE,           08400013
*        X INCREMENTAL, AND Y INCREMENTAL FOR THE POSITIONING           08500013
*        VECTOR.                                                        08600013
*                                                                       08700013
*        WORD 9 CONTAINS X ABSOLUTE.                                    08800013
*                                                                       08900013
*        WORD 10 CONTAINS Y ABSOLUTE.                                   09000013
*                                                                       09100013
*        WORD 11 CONTAINS X INCREMENTAL.                                09200013
*                                                                       09300013
*        WORD 12 CONTAINS Y INCREMENTAL.                                09400013
*                                                                       09500013
*        THE ABOVE WORDS WILL BE SET FROM THE INPUT PASSED AS EITHER    09600013
*        INCREMENTAL OR ABSOLUTE IN USERS UNITS.  SCALE WILL CONVERT    09700013
*        TO RASTER UNITS AND FILL IN THE FORM NOT PASSED.               09800013
*                                                                       09900013
*        WORD 13 CONTAINS THE TOTAL X INCREMENT THUS FAR.               10000013
*                                                                       10100013
*        WORD 14 CONTAINS THE TOTAL Y INCREMENT THUS FAR.               10200013
*                                                                       10300013
*        THE ABOVE WORDS ARE USED IF AN INCREMENTAL REPOSITIONING       10400013
*        VECTOR IS REQUIRED TO REPOSITION WHEN THE ELEMENT IS IN        10500013
*        OMIT STATUS.                                                   10600013
*                                                                       10700013
*        WORD 15 CONTAINS THE ELEMENT COUNT.  IT IS SET TO ZERO         10800013
*        ORIGINALLY AND INCREMENTED BY SCALE. IF THERE IS A             10900013
*        SCALING OR SCISSORING ERROR THE ELEMENT NUMBER IS PLACED       11000013
*        IN THE RETURN ARRAY.                                           11100013
*                                                                       11200013
*                                                                       11300013
         EJECT                                                          11400013
*                                                                       11500013
*        PLINE IS ENTERED AT THE TOP OF THE MODULE AND AFTER SAVING     11600013
*        REGISTERS A REGISTER IS SET TO ZERO AS A SWITCH TO SAY         11700013
*        THAT PLINE WAS CALLED.  PPOINT IS ENTERED AT IFFAFA16 AND      11800013
*        A REGISTER IS SET TO ONE TO SAY THAT PPOINT WAS CALLED.        11900013
*        ALL FUTURE COMMENTS WILL REFER TO THIS MODULE BY THE NAME      12000013
*        PLINE.                                                         12100013
*                                                                       12200013
IFFAFA01 CSECT                     PLINE                                12300013
*2055,270000-272000                                                000A 12350018
*D5395000,D541500                                                A29395 12360021
         ENTRY IFFAFA16                                                 12400013
         USING *,15                                                     12500013
         SAVE  (14,12)                                                  12600013
         LA    REGA,0              SET PLINE FLAG                       12700013
         B     PLT00100                                                 12800013
         DROP  15                                                       12900013
IFFAFA16 SAVE  (14,12)             ENTRY-PPOINT                         13000013
         LA    REGA,1              SET POINT FLAG                       13100013
*                                                                       13200013
*        THE BASE REGISTER IS SET UP, THE WORK AREA DSECT IS            13300013
*        INITIALIZED, AND THE RETURN ARRAY IS INITIALIZED.  THE GDSCB   13400013
*        IS INITIALIZED AND CHECKED FOR VALIDITY.  THE SAVE AREAS       13500013
*        ARE CHAINED.  THE INPUT PARAMETER LIST FOR DATA GEN IS         13600013
*        SET TO ZERO AND THE SKELETON SWITCHES ARE SET.  THE INITIAL    13700013
*        SETTINGS ARE SINGLE ELEMENT, VECTOR, INCLUDE STATUS,           13800013
*        OPTIMIZE OUTPUT, FIRST PASS, NOT KEYED, NOT CORRELATED,        13900013
*        BEAM ON AND A REPOSITIONING VECTOR REQUIRED.  THE GDSCB        14000013
*        ADDRESS AND RETURN ARRAY ADDRESS ARE PLACED IN THE PARAMETER   14100013
*        LIST.  GDSDATMD SWITCH IN THE GDSCB IS SAVED IN CASE IT        14200013
*        MUST BE CHANGED TEMPORARILY FOR SCALE IN THE CASE OF           14300013
*        BUFFER SUBROUTINE MEMBERS REQUIRING INCREMENTAL INPUT.         14400013
*                                                                       14500013
PLT00100 BALR  BASE,0                                                   14600013
         USING *,BASE                                                   14700013
         LR    WORK,PARM           WORK AREA                            14800013
         USING WORKAREA,WORK                                            14900013
         ST    REGA,WRKSWTCH       SET SWITCH FOR LINE OR POINT         15000013
         L     PARM,WRKPARM        LOAD PARM LIST ADDR                  15100013
         L     ERRCD,WRKRTNCD                                           15200013
         XC    0(20,ERRCD),0(ERRCD) ZERO RETURN ARRAY                   15300013
         L     GDSREG,GDS(PARM)    GDS VAR ADDR                         15400013
         L     GDSREG,0(GDSREG)    GDSCB ADDR                           15500013
         USING GDSCB,GDSREG                                             15600013
         MVC   WRKSWTCH+2(1),GDSDATMD  TEMP SETTING OF DZT MODE         15700013
         LA    REGA,WRKSAVE        CHAIN SAVE AREAS                     15800013
         ST    REGA,8(SAVE)                                             15900013
         ST    SAVE,4(REGA)                                             16000013
         LR    SAVE,REGA                                                16100013
         C     GDSREG,GDSGDSCB     IS GDSCB VALID                       16200013
         BNE   ERR1                NO                                   16300013
         XC    WRKSPVSR(12),WRKSPVSR ZERO SUPERVISOR PARAMETER LIST     16400013
         XC    WRKADDR(68),WRKADDR ZERO PARM LIST                       16500013
         MVC   WRKBITS,BITS        MOVE IN SKELETON                     16600013
         ST    GDSREG,WRKGDS       GDSCB ADDR                           16700013
         MVC   WRKRTN,WRKRTNCD     RTN CODE ADDR                        16800013
         TM    GDSFLAGS,SUBR       PART OF SUBR                         16900013
         BZ    PLT00150            YES,GO CHANGE DATA INPUT SWITCH      17000013
         OI    WRKBITS+3,MEMSUB    SET SUBR SW                          17100013
*                                                                       17200013
*        THE PRESENCE OF THE X AND Y PARAMETERS IS CHECKED AND THEY     17300013
*        ARE PICKED UP IN REGISTERS AND PLACED IN THE DATA ARRAY        17400013
*        DEPENDING ON WHETHER THEY ARE INCREMENTAL OR ABSOLUTE.         17500013
         EJECT                                                          17600013
PLT00150 L     REGE,ONE            SET COUNT TO ONE                     17700013
         TM    GDS(PARM),LAST      LAST PARM                            17800013
         BO    ERRPRM              YES-ERROR                            17900013
         L     REGA,X(PARM)        X ADDR                               18000013
         L     REGA,0(REGA)        X VALUE                              18100013
         TM    GDSDATMD,XABS       IS X ABS                             18200013
         BZ    PLT01600            NO                                   18300013
         ST    REGA,WRKXABS                                             18400013
PLT00200 TM    X(PARM),LAST        LAST PARM                            18500013
         BO    ERRPRM                                                   18600013
         L     REGB,Y(PARM)        Y ADDR                               18700013
         L     REGB,0(REGB)        Y VALUE                              18800013
         TM    GDSDATMD,YABS       IS Y ABS                             18900013
         BZ    PLT01700                                                 19000013
         ST    REGB,WRKYABS                                             19100013
*                                                                       19200013
*        IF THE CORVAL IS PASSED AND THE GDS IS NOT A LEVEL 2 GDS       19300013
*        IT IS PLACED IN THE PARAMETER LIST.  IF THE KEY IS PASSED      19400013
*        THE ADDRESS OF THE VARIABLE IS PLACED IN THE PARAMETER         19500013
*        LIST.  IF THE KEY IS A LEVEL 2 KEY THE SWITCH IN THE PARAMETER 19600013
*        LIST IS NOT SET BECAUSE IT WOULD CAUSE THE GENERATION          19700013
*        OF THE INCLUDE/OMIT STRUCTURE WHICH IS USELESS IN A LEVEL 2    19800013
*        ENVIRONMENT.                                                   19900013
PLT00300 TM    Y(PARM),LAST        ANY OPTIONAL PARMS.                  20000013
         BO    PLT02000            NO                                   20100013
         CLC   NULL+1(3,ERRCD),COR+1(PARM) IS CORVAL NULL               20200013
         BE    PLT00400            NO                                   20300013
         TM    GDSFLAGS,LEVEL2                                          20400013
         BO    PLT00400                                                 20500013
         L     REGD,COR(PARM)      LOAD ADDR OF CORVAL                  20600013
         MVC   WRKCORVL,0(REGD)    PLACE CORVAL IN PARM LIST            20700013
         OI    WRKBITS+2,CORRE     SET CORVAL SW                        20800013
PLT00400 TM    COR(PARM),LAST      ANY MORE                             20900013
         BO    PLT02000            NO                                   21000013
         CLC   NULL+1(3,ERRCD),KEY+1(PARM) IS KEY NULL                  21100013
         BE    PLT00500            YES                                  21200013
         MVC   WRKKEY,KEY(PARM)    PLACE ADDR OF KEY IN LIST            21300013
         TM    GDSFLAGS,LEVEL2     LEVEL 2 KEY                          21400013
         BO    PLT00500            YES                                  21500013
         OI    WRKBITS+2,KEYED     NO SET KEYED SO IN PRM LST           21600013
         EJECT                                                          21700013
*                                                                       21800013
*        THE GENCODE IS CHECKED.  IF ONE THE SWITCH IS ALREADY SET.     21900013
*        FOR 2 OR 3 A KEY OR CORVAL MUST BE PRESENT.  A GENCODE OF      22000013
*        2 FOR A LEVEL 2 GDS IS INVALID.  IF THE GENCODE IS THREE,      22100013
*        AND THIS IS A LEVEL 1 GDS THE KEY OR CORVAL IS SEARCHED        22200013
*        FOR IN THE KEY TABLE.                                          22300013
PLT00500 TM    KEY(PARM),LAST      MORE                                 22400013
         BO    PLT02000            NO                                   22500013
         CLC   NULL+1(3,ERRCD),GEN+1(PARM) IS GENCODE NULL              22600013
         BE    PLT00600            NO                                   22700013
         L     REGD,GEN(PARM)      ADDR OF CODE                         22800013
         L     REGD,0(REGD)        CODE                                 22900013
         C     REGD,ONE            INCLUDE                              23000013
         BE    PLT00600            YES ALREADY SET                      23100013
         CLC   WRKCORVL(8),ZERO                                         23200013
         BZ    ERR3                NO                                   23300013
         C     REGD,TWO            OMIT                                 23400013
         BNE   PLT00700            NO                                   23500013
         TM    GDSFLAGS,LEVEL2     LEVEL2                               23600013
         BO    ERR3                YES-ERROR                            23700013
         NI    WRKBITS,OMIT        TURN OFF INCLUDE SW                  23800013
PLT00600 TM    WRKBITS+2,CORRE     CORRELATED                           23900013
         BZ    PLT00950                                                 24000013
         CLC   WRKCORVL,ZERO       IS CORVAL ZERO                       24100013
         BE    ERR4                BAD CORVAL                           24200013
         B     PLT00950                                                 24300013
PLT00620 OI    GDSDATMD,XINTINC    SET X INPUT INTEGER,INC              24400013
         B     PLT02870            P                                    24500013
PLT00640 OI    GDSDATMD,YINTINC    Y INPUT INTEGER INC                  24600013
         B     PLT02880                                                 24700013
         EJECT                                                          24800013
*                                                                       24900013
*        THE LOGICAL START ADDRESS AND THE LENGTH OF THE KEY FOR        25000013
*        THE UPDATE ELEMENT ARE SAVED.                                  25100013
*                                                                       25200013
PLT00700 C     REGD,THREE                                               25300013
         BNE   ERR3                BAD GENCODE                          25400013
         TM    GDSFLAGS,SUBR       ARE WE CURRENTLY GEN A SUBR          25500013
         BO    ERRPRM              YES, THIS CALL INVALID               25600013
         TM    GDSFLAGS,LEVEL2     LEVEL2                               25700013
         BO    PLT01800            SET KEY                              25800013
         TM    WRKBITS+2,KEYED     KEY                                  25900013
         BZ    PLT01900            NO                                   26000013
         L     REGD,KEY(PARM)      LOAD KEY ADDR                        26100013
*//                                                                     26200013
*//      SEARCH ON KEY                                                  26300013
*//                                                                     26400013
         ST    REGD,WRKKADDR       ADDR OF KEY                          26500013
         ST    GDSREG,WRKGDS1      GDSCB                                26600013
         LA    REGD,TWO            CODE TO SEARCH ON KEY                26700013
         ST    REGD,WRKCODE                                             26800013
PLT00800 LA    PARM,WRKGDS1                                             26900013
         L     REGD,GDSGTMCB       GET POINTER TO GTMCB            000A 26960018
         L     REGD,4(REGD)        GET POINTER TO GSPCB            000A 27020018
         L     REGD,FE(REGD)       GET POINTER TO STATUS TABLE     000A 27080018
         L      REGFIFTN,ETE(REGD) GET ADRS OF KEY TABLE MGMT      000A 27140018
         BALR  RETURN,REGFIFTN     BRANCH TO KEY TABLE MGMT        000A 27200018
         LTR   REGFIFTN,REGFIFTN                                        27300013
         BNE   ERRPRM              INVALID KEY                          27400013
         MVC   WRKADDR,0(PARM)     MOVE IN KEY START                    27500013
         TM    4(PARM),INCL        WAS PREVIOUS INCLUDE                 27600013
         BO    PLT00820            YES                                  27700013
         NI    WRKBITS,OMIT        SET TO OMIT                          27800013
PLT00820 MVC   WRKBITS+3(1),7(PARM)    MOVE IN SEQ/SUBR MEMBER SW       27900013
         ST    PARM,WRKKEY         SAVE ADDR OF KEY IN KEY TABLE        28000013
PLT00900 OI    WRKSWTCH,UPDATE     SET UPDATE SWITCH                    28100013
         L     PARM,WRKPARM        RESET REG                            28200013
         EJECT                                                          28300013
*                                                                       28400013
*        THE COUNT IS CHECKED AND IF GREATER THAN ONE THE INDEX AND     28500013
*        INCREMENT PARAMETERS MUST BE CHECKED FOR. IF NONE ARE          28600013
*        PASSED, THE INDEX IS ASSUMED TO BE ONE.  IF BOTH INDEX AND     28700013
*        INCREMENT ARE PASSED, IT IS AN ERROR.  THE PRESENCE OF         28800013
*        ONE OR THE OTHER ARE CHECKED AND FLAGS ARE SET TO SHOW         28900013
*        WHICH ONE WAS PASSED AND THE INCREMENT OR INDEX IS SAVED.      29000013
PLT00950 TM    GEN(PARM),LAST      IS THIS LAST                         29100013
         BO    PLT02000            YES                                  29200013
         CLC   NULL+1(3,ERRCD),CT+1(PARM)  IS COUNT NULL                29300013
         L     REGE,ONE            SET CT=1                             29400013
         BE    PLT02000            YES                                  29500013
         L     REGE,CT(PARM)                                            29600013
         L     REGE,0(REGE)        PLACE COUNT IN REGE                  29700013
         C     REGE,ZERO           IS COUNT=0                           29800013
         BE    PLT02700            YES,RETURN                           29900013
         BL    ERR7                LOWER=ERROR                          30000013
         C     REGE,ONE            COUNT=1                              30100013
         BE    PLT02000            YES                                  30200013
         TM    CT(PARM),LAST       LAST                                 30300013
         BO    PLT01300            YES                                  30400013
         CLC   NULL+1(3,ERRCD),XINDEX+1(PARM) IS X INDEX NULL           30500013
         BE    PLT01000            YES                                  30600013
         L     REGD,XINDEX(PARM)                                        30700013
         L     REGD,0(REGD)                                             30800013
         ST    REGC,WRKTEMP        SAVE NULL VARIABLE                   30900013
         M     REGC,FOUR           MULTIPLY INDEX BY FOUR               31000013
         L     REGC,WRKTEMP        RELOAD REGISTER                      31100013
         ST    REGD,WRKXCHNG       PLACE INDEX IN AREA                  31200013
         OI    WRKSWTCH+1,XINDX                                         31300013
PLT01000 TM    XINDEX(PARM),LAST   IS THIS THE LAST                     31400013
         BO    PLT01300                                                 31500013
         CLC   NULL+1(3,ERRCD),YINDEX+1(PARM) IS Y INDEX NULL           31600013
         BE    PLT01100            YES                                  31700013
         L     REGD,YINDEX(PARM)                                        31800013
         L     REGD,0(REGD)        PICK UP INDEX                        31900013
         ST    REGC,WRKTEMP        SAVE NULL VARIABLE                   32000013
         M     REGC,FOUR           MULTIPLY DISP BY FOUR                32100013
         L     REGC,WRKTEMP        LOAC NULL AGAIN                      32200013
         ST    REGD,WRKYCHNG       PLACE INDEX IN AREA                  32300013
         OI    WRKSWTCH+1,YINDX                                         32400013
         EJECT                                                          32500013
PLT01100 TM    YINDEX(PARM),LAST   IS Y INDEX LAST                      32600013
         BO    PLT01300                                                 32700013
         CLC   NULL+1(3,ERRCD),XINCR+1(PARM) IS X INCR NULL             32800013
         BE    PLT01200            YES                                  32900013
         TM    WRKSWTCH+1,XINDX    XINDEX ALSO PASSED                   33000013
         BO    ERRPRM              YES-ERROR                            33100013
         L     REGD,XINCR(PARM)                                         33200013
         MVC   WRKXCHNG,0(REGD)    SAVE INCR                            33300013
         OI    WRKSWTCH+1,XINC     SET SW                               33400013
PLT01200 TM    XINCR(PARM),LAST    LAST                                 33500013
         BO    PLT01300            YES                                  33600013
         CLC   NULL+1(3,ERRCD),YINCR+1(PARM) IS Y INCR NULL             33700013
         BE    PLT01300                                                 33800013
         TM    WRKSWTCH+1,YINDX    YINDEX PASSED ALSO                   33900013
         BO    ERRPRM              YES,ERROR                            34000013
         L     REGD,YINCR(PARM)                                         34100013
         MVC   WRKYCHNG,0(REGD)    SAVE INCR                            34200013
         OI    WRKSWTCH+1,YINC                                          34300013
PLT01300 TM    WRKSWTCH+1,XINDX+XINC    IS AN X PASSED                  34400013
         BZ    PLT01500                                                 34500013
PLT01400 TM    WRKSWTCH+1,YINDX+YINC    IS A Y PASSED                   34600013
         BM    PLT02000                                                 34700013
         MVC   WRKYCHNG,FOUR            NO                              34800013
         OI    WRKSWTCH+1,YINDX         SET INDEX=4                     34900013
         B     PLT02000                                                 35000013
PLT01500 MVC   WRKXCHNG,FOUR                                            35100013
         OI    WRKSWTCH+1,XINDX         SET INDEX=4                     35200013
         B     PLT01400                                                 35300013
PLT01600 ST    REGA,WRKXINCR       STORE X INCR                         35400013
         B     PLT00200                                                 35500013
PLT01700 ST    REGB,WRKYINCR       STORE Y INCR                         35600013
         B     PLT00300                                                 35700013
PLT01800 L     REGD,KEY(PARM)      LOAD KEY ADDR                        35800013
         MVC   WRKADDR,0(REGD)     PLACE KEY IN PARM LIST               35900013
         B     PLT00900                                                 36000013
PLT01900 CLC   WRKCORVL,ZERO                                            36100013
         BE    ERRPRM              BAD PARM COMBINATION                 36200013
*//                                                                     36300013
*//      SEARCH ON CORVAL KEY RETURNED IN REG1                          36400013
*//                                                                     36500013
         LA    REGD,WRKCORVL       ADDR OF CORVAL                       36600013
         ST    REGD,WRKKADDR       IN PARM LIST                         36700013
         LA    REGD,FIVE           CODE SEARCH ON CORVAL                36800013
         ST    REGD,WRKCODE        IN CODE                              36900013
         ST    GDSREG,WRKGDS1      GDSCB ADDR                           37000013
         B     PLT00800                                                 37100013
         EJECT                                                          37200013
**                                                                      37300013
**       ALL THE PARAMETERS ARE CHECKED WE WILL NOW GET SOME            37400013
**       DATA GENERATED.                                                37500013
**                                                                      37600013
*                                                                       37700013
*        THE SWITCH SET ON ENTRY IN THE REGISTER WHICH HAS SINCE        37800013
*        BEEN PLACED IN STORAGE IS CHECKED FOR VECTOR OR POINT          37900013
*        AND THE SWITCH IS SET IN THE PARAMTEER LIST. IF THE            38000013
*        CALL IS A MULTIPLE CALL THE SWITCH IS SET. IF IT IS            38100013
*        A SEQUENCE MEMBER OR A SUBROUTINE MEMBER THE SWITCH IS         38200013
*        SET. THE OUTPUT MODE IS SET TO INCREMENTAL FOR PART            38300013
*        OF A SUBROUTINE, OTHERWISE IT IS SET ACCORDING TO THE          38400013
*        GDSCURMD.  THE GDSXLAST, GDSYLAST, GDSXCURR, AND GDSYCURR      38500013
*        FIELDS ARE SAVED IN CASE THE CALL FAILS AND RESET IS           38600013
*        NECESSARY. IF NOT UPDATE THE LOGICAL ADDRESS FROM THE          38700013
*        OACB IS PLACED IN THE KEY. IF UPDATE THE UPDATE GDOAS          38800013
*        WILL BE OBTAINED NOW.                                          38900013
PLT02000 TM    WRKSWTCH+3,POINT    POINT                                39000013
         BZ    PLT02100            NO                                   39100013
         OI    WRKBITS,PT          SET SW FOR POINT                     39200013
PLT02100 C     REGE,ONE            MULTIPLE                             39300013
         BE    PLT02150                                                 39400013
         OI    WRKBITS,MULT        SET SW MULTIPLE ENTRY                39500013
PLT02150 TM    WRKSWTCH,UPDATE     IS THIS AN UPDATE                    39600013
         BO    PLT02200            YES BYPASS CHECK                     39700013
         TM    GDSFLAGS,SEQ        PART OF A SEQUENCE                   39800013
         BZ    PLT02200            NO                                   39900013
         OI    WRKBITS+3,MEMSEQ    YES SET SW IN KEY                    40000013
PLT02200 TM    WRKBITS+3,MEMSUB    PART OF A SUBROUTINE                 40100013
         BO    PLT02850            YES, INCREMENTAL                     40200013
         TM    GDSCURMD,OPT        OPTIMIZE                             40300013
         BO    PLT02300            YES, ALREADY SET                     40400013
         TM    GDSCURMD,INC        INCR                                 40500013
         BO    PLT02900            YES                                  40600013
         XI    WRKBITS,ABSSW       SET TO ABSOLUTE                      40700013
PLT02300 MVC   WRKXCURR(4),GDSXCURR SAVE X-Y CURR                       40800013
         MVC   WRKXLAST(8),GDSXLAST SAVE X-Y LAST                       40900013
         TM    WRKSWTCH,UPDATE     UPDATE                               41000013
         BO    PLT03200            YES                                  41100013
         L     REGD,GDSAOACB       OACB                                 41200013
         L     REGD,CURRLOG(REGD)  LOGICAL START                        41300013
         STH   REGD,WRKADDR+2      IN ELEMENT                           41400013
*                                                                       41500013
*        IF THE ELEMENT IS A MULTIPLE ONE THE FUTURE LOOP IS SET        41600013
*        UP. THE ADDRESS OF THE GDSCB IN THE PARAMETER LIST             41700013
*        WE HAVE BEEN BUILDING IS PLACED IN REGISTER 1 AND THE          41800013
*        DATA IS SCALED. IF THE CALL IS TO A BUFFER SUBROUTINE          41900013
*        MEMBER NO SCISSORING WILL TAKE PLACE. IF THE OPTION            42000013
*        IS NO SCISSORING THE GDSXLAST, GDSYLAST, GDSXCURR,             42100013
*        AND GDSYCURR FIELDS IN THE GDSCB ARE UPDATED. THE              42200013
*        SCISSORING FLAGS ARE ALSO SET SUCH THAT IT APPEARS AS          42300013
*        IF THE LAST CALL WAS ON THE SCREEN AND ON THE GRID.            42400013
PLT02350 OI    WRKSWTCH,FIRST      SET FIRST TIME SWITCH SO THAT THE    42500013
*        FIRST CALL TO DATA GENERATOR IS NOT BYPASSED BECAUSE OF NO     42600013
*        MOVEMENT FROM THE LAST BEAM POSITION                           42700013
         C     REGE,ONE            MORE THAN ONE                        42800013
         BH    PLT03400            YES SET UP FUTURE LOOP               42900013
         EJECT                                                          43000013
*                                                                       43100013
*        COUNT IN REGE   X IN REGA  Y IN REGB                           43200013
*                                                                       43300013
PLT02400 LA    PARM,WRKGDS                                              43400013
*/*                                                                     43500013
*/*      CALL  SCALE                                                    43600013
*/*                                                                     43700013
         L     REGFIFTN,STAT(ERRCD) ADDR OF STATUS TABLE                43800013
         L     REGFIFTN,SCALE(REGFIFTN) ADDRESS OF SCALE                43900013
         BALR  RETURN,REGFIFTN     BRANCH TO SCALE                      44000013
         LTR   REGFIFTN,REGFIFTN   SCALE OK                             44100013
         BNE   ERR10               RESET AND RETURN                     44200013
         TM    GDSFLAGS,SUBR       SUBR                                 44300013
         BO    PLT02450            NO SCISS OR CHANGE OF BEAM IN GDSCV  44400013
         TM    GDSSCISS,NOSCISS    NO SCISS WANTED                      44500013
         BO    PLT03000            NONE                                 44600013
         LA    PARM,WRKGDS                                              44700013
*//      CALL SCISSOR                                                   44800013
*//                                                                     44900013
         L     REGFIFTN,STAT(ERRCD)                                     45000013
         L     REGFIFTN,SCISS(REGFIFTN) ADDRESS OF SCISSOR              45100013
         BALR  RETURN,REGFIFTN                                          45200013
         LTR   REGFIFTN,REGFIFTN   ERROR                                45300013
         BNE   PLT03100            YES                                  45400013
         TM    WRKSWTCH,FIRST      FIRST ONE                            45500013
         BO    PLT02450            YES, GENERATE ANYWAY                 45600013
         CLC   WRKXINCR(8),ZERO    ANY MOVEMENT?                        45700013
         BE    PLT02500            NO-DON'T GENERATE                    45800013
         EJECT                                                          45900013
         L     REGFIFTN,GDSGTMCB        GET POINTER TO GTMCB     A57058 45950021
         L     REGFIFTN,GSPPTR(REGFIFTN) GET POINTER TO GSPCB.   A57058 45960021
         TM    ARRAY(REGFIFTN),SCISORED WAS SCISSORING USED?     A57058 45970021
         BZ    PLT02450                 BRANCH IF NO.            A57058 45980021
         TM    WRKSWTCH+3,PLTPTNT       WAS POINT SCISSORED?     A57058 45990021
         BZ    PLT02450                 BRANCH IF NO.            A57058 45992021
         NI    WRKBITS+2,BLANK          SET FLAGS SO DATA GEN... A57058 45994021
*                                       WILL BLANK THE BEAM      A57058 45996021
PLT02450 LA    PARM,WRKADDR                                             46000013
*//                                                                     46100013
*//      CALL DATA GEN                                                  46200013
*//                                                                     46300013
         L     REGFIFTN,STAT(ERRCD)                                     46400013
         L     REGFIFTN,DGEN(REGFIFTN)  ADDRESS OF DATA GEN             46500013
         BALR  RETURN,REGFIFTN                                          46600013
         LTR   REGFIFTN,REGFIFTN   ERROR                                46700013
         BNE   ERR10               RESET AND RETURN                     46800013
         NI    WRKSWTCH,OFF        TURN OFF FIRST SWITCH                46900013
*                                                                       47000013
*        THE VECTOR OR POINT IS GENERATED BY DATA GEN AND               47100013
*        STORED IN THE GDOA BY DATA STORE.  IF THERE ARE NO             47200013
*        MORE TO DO THE UPDATE GDOAS ARE WRITTEN OUT IF UPDATE,         47300013
*        OR THE KEY IS COMPLETED AND PLACED IN THE KEY TABLE IF         47400013
*        NECESSARY AND IN THE USER VARIABLE IF PASSED.  THE             47500013
*        SWITCHES IN THE GDSDATMD FIELD ARE RESET AND CONTROL           47600013
*        IS RETURNED TO THE CALLING PROGRAM.                            47700013
*                                                                       47800013
PLT02500 BCT   REGE,PLT03700       MORE TO DO                           47900013
         TM    WRKSWTCH,FIRST      HAS ANY DATA BEEN GEN                48000013
         BO    ERR8                NO                                   48100013
         TM    WRKSWTCH,LSTONE     WAS LAST ONE GENERATED               48200013
         BZ    PLT02550            YES                                  48300013
         OI    WRKBITS+2,REPONLY   SET FLAG TO GEN REPOS VECT           48400013
         XC    WRKDATA1(32),WRKDATA1                                    48500013
         MVC   WRKXABS+2(2),GDSXCURR    PLACE CURRENT BEAM POSITION     48600013
         MVC   WRKYABS+2(2),GDSYCURR FROM GDS INTO DATA ARRAY           48700013
         LA    REGE,1              RESET COUNT TO FALL THROUGH          48800013
         B     PLT02450            CALL DATA GEN                        48900013
PLT02550 TM    WRKSWTCH,UPDATE     UPDATE                               49000013
         BO    PLT03300            YES                                  49100013
         L     REGE,GDSAOACB       NO                                   49200013
         L     REGE,CURRLOG(REGE)  GET CURR LOG ADDR                    49300013
         SH    REGE,WRKADDR+2      COMPUTE ELEM LEN                     49400013
         LTR   REGE,REGE           ANY DATA GENERATED                   49500013
         BE    ERR8                NO ERROR                             49600013
         STH   REGE,WRKADDR        PLACE LENGTH IN KEY                  49700013
         L     REGE,WRKKEY                                              49800013
         LTR   REGE,REGE                                                49900013
         BE    PLT02600                                                 50000013
         MVC   0(4,REGE),WRKADDR   PLACE KEY IN USER VARIABLE           50100013
PLT02600 TM    WRKBITS+2,KEYED+CORRE KEYED OR CORRELATED                50200013
         BZ    PLT02700            NO                                   50300013
*//                                                                     50400013
*//      CALL KEY TABLE TO ADD KEY                                      50500013
*//                                                                     50600013
         ST    GDSREG,WRKGDS1      GDSCB FOR KEY TABLE MGT              50700013
         LA    REGA,ONE            CODE                                 50800013
         ST    REGA,WRKCODE        IN PARM LIST                         50900013
         LA    REGA,WRKADDR        ADDR OF KEY                          51000013
         ST    REGA,WRKKADDR       IN PARM LIST                         51100013
         LA    PARM,WRKGDS1                                             51200013
         L     REGA,16             CVT                                  51300013
         L     REGA,CVTLINK(REGA)  LINK LIB DCB                         51400013
         LINK  EP=IFFAHA03,MF=(E,(1)),SF=(E,WRKSPVSR)                   51500013
         LTR   REGFIFTN,REGFIFTN   SUCCESSFUL                           51600013
         BNE   ERR9                NO                                   51700013
PLT02700 L     SAVE,4(SAVE)                                             51800013
         MVC   GDSDATMD,WRKSWTCH+2 RESET DATA MODE                      51900013
PLT02800 RETURN (14,12),T          RETURN                               52000013
         EJECT                                                          52100013
*                                                                       52200013
*        IF THIS CALL IS TO GENERATE DATA THAT IS TO BE PART OF A       52300013
*        BUFFER SUBROUTINE, THE GDSDATMD SWITCH IS CHANGED TO           52400013
*        REFLECT EITHER REAL OR INTEGER INCREMENTAL DATA AS INPUT.      52500013
PLT02850 XC    GDSDATMD,GDSDATMD   ZERO DATA MODE SW                    52600013
         TM    WRKSWTCH+2,REALX    REAL                                 52700013
         BZ    PLT00620            NO                                   52800013
         OI    GDSDATMD,XRELINC    SET X INPUT REAL,INC                 52900013
PLT02870 TM    WRKSWTCH+2,REALY    REAL                                 53000013
         BZ    PLT00640            NO                                   53100013
         OI    GDSDATMD,YRELINC    SET Y INPUT REAL,INC                 53200013
PLT02880 XC    WRKXABS(16),WRKXABS                                      53300013
         ST    REGA,WRKXINCR      SET X INCREMENTAL                     53400013
         ST    REGB,WRKYINCR      SET Y INCREMENTAL                     53500013
PLT02900 XI    WRKBITS,INCSW                                            53600013
         B     PLT02300                                                 53700013
PLT03000 L     PARM,WRKXABS        LOAD X                               53740013
         ST    PARM,GDSXLAST       STORE IN LAST LOC                    53780013
         SH    PARM,GDSXCURR       COMPUTE NEW INCR                     53820013
         ST    PARM,WRKXINCR       STORE                                53860013
         MVC   GDSXCURR,WRKXABS+2      XCURR                            53900013
         L     PARM,WRKYABS        LOAD Y                               53980013
         ST    PARM,GDSYLAST       STORE IN LAST LOC                    54010013
         SH    PARM,GDSYCURR       COMPUTE NEW INCR                     54040013
         ST    PARM,WRKYINCR       STORE                                54070013
         MVC   GDSYCURR,WRKYABS+2      YCURR IN GDSCB                   54100013
         NI    GDSSCISS,LASTON                                          54200013
         B     PLT02450                                                 54300013
PLT03100 C     REGFIFTN,FOUR            STOP GENERATION                 54400013
         BE    ERR10               YES, RESET AND RETURN                54500013
         B     PLT02500                                                 54600013
*//      GET GDOA'S FOR UPDATE                                          54700013
PLT03200 L     REGD,16             CVT                                  54800013
         L     REGD,CVTLINK(REGD)  LINK LIB DCB                         54900013
         LA    PARM,WRKADDR                                             55000013
         LINK  EP=IFFAHA13,MF=(E,(1)),SF=(E,WRKSPVSR)                   55100013
         LTR   REGFIFTN,REGFIFTN   SUCCESS                              55200013
         BNE   PLT02700            NO                                   55300013
         B     PLT02350                                                 55400013
         EJECT                                                          55500013
*/                                                                      55600013
*//      WRITE OUT UPDATE                                               55700013
PLT03300 L     REGD,16                                                  55800013
         L     REGD,CVTLINK(REGD)                                       55900013
         LA    PARM,WRKADDR                                             56000013
         LINK  EP=IFFAHA14,MF=(E,(1)),SF=(E,WRKSPVSR)                   56100013
         TM    GDSFLAGS,LEVEL2                                          56120013
         BO    PLT02700                                                 56140013
         L     REGD,WRKKEY                                              56160013
         MVC   0(8,REGD),WRKADDR   REPLACE KEY                          56180013
         TM    WRKBITS+2,CORRE     IS IS IT CORRELATED                  56200013
         BZ    PLT02700            NO EXIT                              56300013
         L     REGD,WRKKEY         ADDR OF KEY IN KEY TABLE             56400013
         MVC   8(4,REGD),WRKCORVL  REPLACE CORVAL                       56500013
         B     PLT02700                                                 56600013
PLT03400 L     PARM,WRKPARM        RESET REG                            56700013
         TM    WRKSWTCH+1,XINDX    X INDEX                              56800013
         BO    PLT03600            YES                                  56900013
PLT03500 TM    WRKSWTCH+1,YINDX    Y INDEX                              57000013
         BZ    PLT02400            NO                                   57100013
         L     REGB,Y(PARM)        REP Y VAL WITH Y ADDR                57200013
         B     PLT02400                                                 57300013
         EJECT                                                          57400013
PLT03600 L     REGA,X(PARM)        REP X VAL WITH X ADDR                57500013
         B     PLT03500                                                 57600013
*                                                                       57700013
*        IN ORDER TO GENERATE THE NEXT DATA THE DATA FIELDS IN          57800013
*        THE PARAMETER LIST ARE ZEROED.  THE NOT FIRST NOT              57900013
*        LAST SWITCH IS SET. IF THIS IS THE LAST TIME THEN THE          58000013
*        LAST SWITCH IS SET. THE ARRAY IS INDEXED THROUGH OR            58100013
*        THE INCREMENT IS ADDED TO THE PREVIOUS DATA TO FORM            58200013
*        THE NEW DATA. THEN SCALE IS CALLED, SCISSOR, ETC.              58300013
*                                                                       58400013
PLT03700 XC    WRKDATA1(32),WRKDATA1 ZERO DATA                          58500013
         TM    WRKSWTCH,FIRST      HAS ANY DATA BEEN GENERATED YET      58600013
         BO    PLT03730            NO SO DONT CHANGE THE FIRST SW IN PL 58700013
         OI    WRKBITS+2,NFNL      SET NOT FIRST LAST SWITCH            58800013
PLT03730 C     REGE,ONE            IS THIS THE LAST ONE                 58900013
         BE    PLT04900            LAST TIME                            59000013
PLT03750 TM    WRKSWTCH+1,XINDX    INDEX X                              59100013
         BZ    PLT04100            NO                                   59200013
         A     REGA,WRKXCHNG                                            59300013
         TM    GDSDATMD,ABSOLX     X ABS                                59400013
         BZ    PLT03900                                                 59500013
         MVC   WRKXABS,0(REGA)     MOVE IN X ABS                        59600013
PLT03800 TM    WRKSWTCH+1,YINDX    Y INDEX                              59700013
         BZ    PLT04300            NO                                   59800013
         A     REGB,WRKYCHNG                                            59900013
         TM    GDSDATMD,ABSOLY     Y ABS                                60000013
         BZ    PLT04000            NO                                   60100013
         MVC   WRKYABS,0(REGB)     MOVE IN Y ABS                        60200013
         B     PLT02400                                                 60300013
PLT03900 MVC   WRKXINCR,0(REGA)    MOVE IN X INCR                       60400013
         B     PLT03800                                                 60500013
PLT04000 MVC   WRKYINCR,0(REGB)    MOVE IN Y INCR                       60600013
         B     PLT02400                                                 60700013
         EJECT                                                          60800013
PLT04100 TM    GDSDATMD,REALX      X IN FLOAT                           60900013
         BM    PLT04500            YES                                  61000013
         A     REGA,WRKXCHNG       ADD X INCRE                          61100013
PLT04200 TM    GDSDATMD,ABSOLX     ABSOLUTE                             61200013
         BZ    PLT04600            NO                                   61300013
         ST    REGA,WRKXABS        STORE IN ABS LOC                     61400013
         B     PLT03800            CHECK Y                              61500013
PLT04300 TM    GDSDATMD,REALY      Y REAL                               61600013
         BM    PLT04700            YES                                  61700013
         A     REGB,WRKYCHNG       ADD Y INCR                           61800013
PLT04400 TM    GDSDATMD,ABSOLY     Y ABS                                61900013
         BZ    PLT04800            NO                                   62000013
         ST    REGB,WRKYABS        STORE IN ABS                         62100013
         B     PLT02400                                                 62200013
PLT04500 ST    REGA,WRKTEMP        STORE # IN CORE                      62300013
         LE    FLT2,WRKTEMP                                             62400013
         AE    FLT2,WRKXCHNG       ADD INCR IN FLOAT INSTR              62500013
         STE   FLT2,WRKTEMP                                             62600013
         L     REGA,WRKTEMP        REPLACE IN REG                       62700013
         B     PLT04200                                                 62800013
PLT04600 MVC   WRKXINCR,WRKXCHNG   STORE X IN INCR                      62900013
         B     PLT03800            CHECK Y                              63000013
PLT04700 ST    REGB,WRKTEMP        STORE IN CORE                        63100013
         LE    FLT2,WRKTEMP                                             63200013
         AE    FLT2,WRKYCHNG       ADD Y INCR IN                        63300013
         STE   FLT2,WRKTEMP        FLOAT INSTR                          63400013
         L     REGB,WRKTEMP        RELOAD REG                           63500013
         B     PLT04400                                                 63600013
PLT04800 MVC   WRKYINCR,WRKYCHNG   STORE Y INCR                         63700013
         B     PLT02400                                                 63800013
PLT04900 TM    WRKSWTCH,FIRST      ANY GENERATED YET                    63900013
         BO    PLT05000            NO CHANGE ENTRY TO SINGEL            64000013
         OI    WRKBITS+2,LASTIN    SET LAST TIME SWITCH                 64100013
         OI    WRKSWTCH,LSTONE     SET SWITCH TO SAY LAST TIME IN       64200013
         B     PLT03750            CONTINUE ON                          64300013
PLT05000 XI    WRKBITS,MULT        MULTIPLE ENTRY HAS BECOME A SINGLE   64400013
         B     PLT03750            CONTINUE                             64500013
         EJECT                                                          64600013
ERR1     MVC   PARMERR(4,ERRCD),ONE GDS INVALID                         64700013
ERRPRM   OI    0(ERRCD),PRM        PARM ERROR                           64800013
         B     PLT02700                                                 64900013
ERR3     MVC   PARMERR(4,ERRCD),SIX GENCODE                             65000013
         B     ERRPRM                                                   65100013
ERR4     MVC   PARMERR(4,ERRCD),FOUR CORVAL                             65200013
         B     ERRPRM                                                   65300013
ERR7     MVC   PARMERR(4,ERRCD),SEVEN COUNT                             65400013
ERR8     OI    0(ERRCD),SCISSOR    NO DATA GEN                          65500013
         XC    4(4,ERRCD),4(ERRCD) ZERO SCISSOR COUNT                   65600013
         B     PLT02700                                                 65700013
ERR9     OI    0(ERRCD),STRG       MAIN STORAGE EXCEEDED                65800013
         MVC   STOR(4,ERRCD),FOUR                                       65900013
ERR10    MVC   GDSXLAST(8),WRKXLAST RESET SYSTEM                        66000013
         MVC   GDSXCURR(4),WRKXCURR                                     66100013
         TM    WRKSWTCH,UPDATE     UPDATE                               66200013
         BO    PLT02700            NO RESET RQD                         66300013
*//                                                                     66400013
*//      CALL RESET TO RESET SYSTEM                                     66500013
*//                                                                     66600013
         MVC   WRKDATA2(20),0(ERRCD)   SAVE RETURN ARRAY                66700013
         LA    REGA,GDSGDSCB       VAR CONTAINING ADDR OF GDS           66800013
         ST    REGA,WRKGDS         IN PARAMETER LIST                    66900013
         L     REGA,NULL(ERRCD)    NULL FOR CORVAL                      67000013
         ST    REGA,WRKRTN         IN PARM LIST                         67100013
         LA    REGA,WRKADDR        ADDRESS OF KEY                       67200013
         ST    REGA,WRKDATA1       IN PARAMETER LIST                    67300013
         OI    WRKDATA1,LAST       LAST PARM SW                         67400013
         LA    REGA,WRKGDS         ADDR OF PARM LIST                    67500013
         ST    REGA,WRKGDS1        IN WORK AREA                         67600013
         ST    ERRCD,WRKCODE       ERROR CODE IN PARM LIST              67700013
         LA    PARM,WRKGDS1        ADDR OF WRK AREA IN R1               67800013
         LINK  EP=IFFAFA12,MF=(E,(1)),SF=(E,WRKSPVSR)                   67900013
*        LINK TO RESET ROUTINE                                          68000013
         MVC   0(20,ERRCD),WRKDATA2                                     68100013
*        RESET RETURN ARRAY                                             68200013
         B     PLT02700                                                 68300013
         EJECT                                                          68400013
* REGISTERS                                                             68500013
REGZERO  EQU   0                                                        68600013
PARM     EQU   1                                                        68700013
REGA     EQU   2                                                        68800013
REGB     EQU   3                                                        68900013
REGE     EQU   4                                                        69000013
WORK     EQU   5                                                        69100013
ERRCD    EQU   6                                                        69200013
GTMREG   EQU   7                                                        69300013
GDSREG   EQU   8                                                        69400013
BASE     EQU   9                                                        69500013
REGC     EQU   10                                                       69600013
REGD     EQU   11                                                       69700013
SAVE     EQU   13                                                       69800013
RETURN   EQU   14                                                       69900013
REGFIFTN EQU   15                                                       70000013
FLT2     EQU   2                   FLOATING PT REG                      70100013
         EJECT                                                          70200013
ZERO     DC    2F'0'                                                    70300013
ONE      DC    F'1'                                                     70400013
TWO      DC    F'2'                                                     70500013
THREE    DC    F'3'                                                     70600013
FOUR     DC    F'4'                                                     70700013
BITS     DC    B'00000111'         SINGLE,VECTOR,INCLUDE,OPTIMIZE       70800013
         DC    X'00'                                                    70900013
         DC    B'00001000'         FIRST PASS,NOT KEY,COR,BEAMON,REPOS  71000013
         DC    X'00'                                                    71100013
SIX      DC    F'6'                                                     71200013
SEVEN    DC    F'7'                                                     71300013
SCISSOR  EQU   X'40'                                                    71400013
FE       EQU   48                                                  000A 71430018
ETE      EQU   828                                                 000A 71460018
         EJECT                                                          71500013
OMIT     EQU   X'FB'                                                    71600013
XINDX    EQU   X'C0'                                                    71700013
YINDX    EQU   X'0C'                                                    71800013
XINC     EQU   X'30'                                                    71900013
YINC     EQU   X'03'                                                    72000013
MULT     EQU   X'80'                                                    72100013
OPT      EQU   X'04'                                                    72200013
ABS      EQU   X'02'                                                    72300013
ABSSW    EQU   X'03'                                                    72400013
INCSW    EQU   X'02'                                                    72500013
SUBR     EQU   X'02'                                                    72600013
INC      EQU   X'01'                                                    72700013
NOSCISS  EQU   X'10'                                                    72800013
LASTON   EQU   X'1F'                                                    72900013
CURRLOG  EQU   52                                                       73000013
ABSOLX   EQU   X'A0'                                                    73100013
ABSOLY   EQU   X'0A'                                                    73200013
REALX    EQU   X'C0'                                                    73300013
REALY    EQU   X'0C'                                                    73400013
PT       EQU   X'10'                                                    73500013
NULL     EQU   20                                                       73600013
LAST     EQU   X'80'                                                    73700013
XABS     EQU   X'A0'                                                    73800013
YABS     EQU   X'0A'                                                    73900013
CORRE    EQU   X'10'                                                    74000013
KEYED    EQU   X'20'                                                    74100013
LEVEL2   EQU   X'10'                                                    74200013
POINT    EQU   X'01'                                                    74300013
MEMSUB   EQU   X'80'                                                    74400013
MEMSEQ   EQU   X'40'                                                    74500013
SEQ      EQU   X'04'                                                    74600013
XINTINC  EQU   X'10'                                                    74700013
XRELINC  EQU   X'40'                                                    74800013
YINTINC  EQU   X'01'                                                    74900013
YRELINC  EQU   X'04'                                                    75000013
EVENFOUR EQU   X'FC'                                                    75050013
ARRAY    EQU   X'18'                    OFFSET TO GSPARRAY       A57058 75060021
GSPPTR   EQU   4                        OFFSET TO GSPCB IN GTMCB A57058 75070021
SCISORED EQU   X'40'                    SCISSOR FLAGS IN ARRAY   A57058 75080021
PLTPTNT  EQU   X'01'                    PLOT POINT FLAGS         A57058 75090021
BLANK    EQU   X'F7'                    BLANK BEAM BIT MASK.     A57058 75092021
* PARM LIST EQUATES                                                     75100013
GDS      EQU   0                                                        75200013
X        EQU   4                                                        75300013
Y        EQU   8                                                        75400013
COR      EQU   12                                                       75500013
KEY      EQU   16                                                       75600013
GEN      EQU   20                                                       75700013
CT       EQU   24                                                       75800013
XINDEX   EQU   28                                                       75900013
YINDEX   EQU   32                                                       76000013
XINCR    EQU   36                                                       76100013
YINCR    EQU   40                                                       76200013
PARMERR  EQU   16                                                       76300013
PRM      EQU   X'08'                                                    76400013
STRG     EQU   X'10'                                                    76500013
STOR     EQU   12                                                       76600013
NFNL     EQU   X'40'                                                    76700013
LASTIN   EQU   X'C0'                                                    76800013
DGEN     EQU   840                                                      76900013
SCISS    EQU   876                                                      77000013
SCALE    EQU   864                                                      77100013
STAT     EQU   24                                                       77200013
FIVE     DC    F'5'                                                     77300013
CVTLINK  EQU   8                                                        77400013
INCL     EQU   X'04'                                                    77500013
REPONLY  EQU   X'02'                                                    77600013
FIRST    EQU   X'02'                                                    77700013
LSTONE   EQU   X'01'                                                    77800013
OFF      EQU   X'FC'                                                    77900013
UPDATE   EQU   X'80'                                                    78000013
         EJECT                                                          78100013
WORKAREA DSECT                                                          78200013
WRKPARM  DS    F                                                        78300013
WRKRTNCD DS    F                                                        78400013
WRKSWTCH DS    F                                                        78500013
*        SWITCH SETTINGS FOR WRKSWTCH - PLINE AND PPOINT                78600013
*                                                                       78700013
*        WRKSWTCH+1                                                     78800013
*        C0 = X INDEX PASSED                                            78900013
*        30 = X INCREMENT PASSED                                        79000013
*        0C = Y INDEX PASSED                                            79100013
*        03 = Y INCREMENT PASSED                                        79200013
*                                                                       79300013
*        WRKSWTCH+2                                                     79400013
*        80 = X IS REAL,ABSOLUTE                                        79500013
*        40 = X IS REAL,INCREMENTAL                                     79600013
*        20 = X IS INTEGER,ABSOLUTE                                     79700013
*        10 = X IS INTEGER,INCREMENTAL                                  79800013
*        08 = Y IS REAL,ABSOLUTE                                        79900013
*        04 = Y IS REAL,INCREMENTAL                                     80000013
*        02 = Y IS INTEGER,ABSOLUTE                                     80100013
*        01 = Y IS INTEGER,INCREMENTAL                                  80200013
*                                                                       80300013
*        WRKSWTCH+3                                                     80400013
*        00 = PLINE                                                     80500013
*        O1 = PPOINT                                                    80600013
*                                                                       80700013
WRKSAVE  DS    18F                                                      80800013
WRKSPVSR DS    3F                                                       80900013
WRKXCURR DS    H                                                        81000013
WRKYCURR DS    H                                                        81100013
WRKXLAST DS    F                                                        81200013
WRKYLAST DS    F                                                        81300013
WRKXCHNG DS    F                                                        81400013
WRKYCHNG DS    F                                                        81500013
WRKTEMP  DS    F                                                        81600013
WRKADDR  DS    F                                                        81700013
WRKBITS  DS    F                                                        81800013
WRKCORVL DS    F                                                        81900013
WRKKEY   DS    F                                                        82000013
WRKGDS   DS    F                                                        82100013
WRKRTN   DS    F                                                        82200013
WRKDATA1 DS    F                                                        82300013
WRKDATA2 DS    F                                                        82400013
WRKDATA3 DS    F                                                        82500013
WRKDATA4 DS    F                                                        82600013
WRKXABS  DS    F                                                        82700013
WRKYABS  DS    F                                                        82800013
WRKXINCR DS    F                                                        82900013
WRKYINCR DS    F                                                        83000013
WRKTOTX  DS    F                                                        83100013
WRKTOTY  DS    F                                                        83200013
WRKENTCT DS    F                                                        83300013
WRKGDS1  DS    F                                                        83400013
WRKCODE  DS    F                                                        83500013
WRKKADDR DS    F                                                        83600013
         COPY  GDSCB                                                    83700013
         COPY  GTMCB                                                    83800013
         COPY  GSPCB                                                    83900013
         END                                                            84000013